Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3975
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohammed, Mustafa Mohammed Mohammed Ahmed
dc.contributor.authorSupervisor-,Mohammed Ahmed Ali Omer
dc.date.accessioned2014-03-18T10:07:47Z
dc.date.available2014-03-18T10:07:47Z
dc.date.issued2013-03-01
dc.identifier.citationMohammed,stafa Mohammed Mohammed Ahmed.Assessment of Ionization Chambers Performance Using Standard Source Co60/Mustafa Mohammed Mohammed AhmedMohammed;Mohammed Ahmed Ali Omer.-Khartoum : sudan university of science and technology,Medical Radiologic Science,2013.-51p. : ill . ;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/3975
dc.descriptionThesisen_US
dc.description.abstractUnderstanding quality control and calibration of ionization chambers which are used as dosimeters in department of radiotherapy at RICK by using standard sources of cobalt 60 as well as acquiring necessary and sufficient training are considered as very important for clinical dosimetry. The aims of this study were:8 1- to assess the performance of the Ionization chambers using standard sources co60, 2- Determine the efficiency and accuracy of Ionization Chambers, 3-Compare between the responses of different ionization chambers at RICK with reference ion chamber, 4- Create a conversion factors of different type of ionization chambers by using reference chamber. Three co60 sources with different activities and water phantom and slap phantom were used to achieve a high evaluation of ion chambers, accuracy and efficiency. The total uncertainty in the determination of the dose to water during calculation of the beam was found to be less than 1% and this magnitude within the accepted limits of recommendation of the IAEA protocol 2%. All ion chambers used in this study showed good precision (reproducibility), linearity and accuracy, except one ion chamber which is FC65-G with uncertainty of which is out of limit 7%.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectAssessmenten_US
dc.subjectIonizationen_US
dc.titleAssessment of Ionization Chambers Performance Using Standard Source Co60en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Ionization .pdf
  Restricted Access
Research1.3 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.