Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3959
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHabiballah, Hamd Elniel Hassan
dc.contributor.authorSupervised,-Mohammed Ahmed Ali Omer
dc.date.accessioned2014-03-17T11:19:11Z
dc.date.available2014-03-17T11:19:11Z
dc.date.issued2013-05-01
dc.identifier.citationHabiballah,Hamd Elniel Hassan. Measurement of the height difference between right and left hemi diaphragm in normal Sudanese adult using postero-anterior chest Measurement/Hamd Elniel Hassan Habiballah;Caroline Edward Ayad.-Khartoum : sudan university of science and technology,Medical Radiologic Science.-41p. : ill . ;28cm.- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/3959
dc.descriptionThesisen_US
dc.description.abstractThe following thesis is about an assessment of medical ultrasound resolution using polymer gel. The study has been done at faculty of x-ray science .During a period of time extended from may2012 till January2013. Using four sample of known companies in medical instruments (Siemens-Aloka-Philips-Shimadzu).The study evaluate axial resolution and lateral resolution versus aging of ultrasound systems, and maximum depth visualization for different types of ultrasound probes (different frequencies 4mhz-7mhz).The data has been analyzed by excel and it revealed that Philips system were showing the most tolerable ones in view of life change and aging influence. The study revealed that Siemens system showed the most influencing one by aging and the average shiftiness was 1.8 mm, then Aloka showed 1.3 mm, then Shimadzu showed 0.8 mm and the last influencing system by aging was Philips which showed 0.7 mm..The study revealed that the vertical shift for the system Siemens, Aloka, Shimadzu and Philips were as follows: 1, 0.8, 0.6 and 0.6 mm respectively. The study revealed that lateral resolution for the systems Siemens, Aloka, Shimadzu and Philips were as follows 0.9, 0.7, 0.5 and 0.2 mm respectively. The study revealed that maximum depth of visualization increase at low frequencies Probes while the shallow visualized depth related to high frequencies Probes, a probe of 4 MHz visualized depth was 16 cm and 7 MHz probe visualized depth was 15 cm.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectAssessmenten_US
dc.subjectResolutionen_US
dc.titleMeasurement of the height difference between right and left hemi diaphragm in normal Sudanese adult using postero-anterior chest Measurementen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Medical ...pdf
  Restricted Access
Research824.95 kBAdobe PDFView/Open Request a copy
Abstract.pdfAbstract46 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.