Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3312
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYosif, Rasha Ibrahim-
dc.date.accessioned2014-01-30T12:06:28Z-
dc.date.available2014-01-30T12:06:28Z-
dc.date.issued2007-09-01-
dc.identifier.citationYosif,Rasha Ibrahim.Investigation of the Concentration Goodness for Some Drugs Using Light Angular Scattering/Rasha Ibrahim Yosif;Mubarak ElMahal Ahmed.-Khartoum:Sudan University of Science and Technology,College of Science,2007.-124p. : ill. ; 28cm.-M.SC.en_US
dc.identifier.urihttp://hdl.handle.net/123456789/3312-
dc.descriptionThesisen_US
dc.description.abstractIn this work a simple setup was build to measure the angular scattering of laser light to test the quality of some medical solutions (concentration) and detect any change in the concentration from the standard concentration which must be suitable for desired dose. In this setup diode laser with wavelength 671 nm and output power 100 mW and photomultiplayer tube were used to find the relation between sample concentration and transmitted intensity at zero angle, and scattered intensities at angles 450,900 and 1350 for the following samples: Sugar and Sodium Chloride (NaCl) as standard samples, to calibrate the setup and to study the behavior of the scattered light, and other targeted samples: Benzylpenicillin Sodium (BS), Metronidazole and Actrapid HM (Insulin Human) (IH). The results showed that the relation between the transmitted intensity and sample concentration is inverse linear relation. Also, the relation between the angular scattered intensity and sample concentration is linear relation. The study proved that, this setup is very sensitive to detect the scattered laser intensity at any change in sample concentration from its standard concentration. It was found that, a change in the concentration of BS sample, as example by (0.04), the setup gave clear reading of this change. Also, a change in the concentration of (IH) sample by (0.025) gave clear differences in scattered intensity at all angles for this very little change. From the characteristics mentioned above it is clear that, this setup is very efficient in discovering any manipulation in the drug dose.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectPhysicsen_US
dc.subjectlaser Lighten_US
dc.titleInvestigation of the Concentration Goodness for Some Drugs Using Light Angular Scatteringen_US
dc.title.alternativeفحص جودة تركيز بعض الأدوية باستخدام الاستطارة الزاوّية للضوءen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Science

Files in This Item:
File Description SizeFormat 
Investigation of the Concentration Goodness ... .pdftitle36.89 kBAdobe PDFView/Open
Abstract.pdfAbstract101.65 kBAdobe PDFView/Open
chapter 1.pdf
  Restricted Access
chapter 183.58 kBAdobe PDFView/Open Request a copy
chapter2.pdf
  Restricted Access
chapter 285.13 kBAdobe PDFView/Open Request a copy
chapter 3.pdf
  Restricted Access
chapter 1.17 MBAdobe PDFView/Open Request a copy
chapter 4.pdf
  Restricted Access
chapter 268.88 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.