Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3181
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbdallah, Salma Babiker-
dc.date.accessioned2014-01-20T12:02:40Z-
dc.date.available2014-01-20T12:02:40Z-
dc.date.issued2009-06-01-
dc.identifier.citationAbdallah , Salma Babiker .Evaluation of Quality Control in Radiotherapy Departments of the National Oncology Centers, In Sudan for Simulator and Cobalt-60/Salma Babiker Abdallah ;.-Khartoum:Sudan University of Science and Technology,College of Science,2009.-71p. : ill. ; 28cm.-M.Sc.en_US
dc.identifier.urihttp://hdl.handle.net/123456789/3181-
dc.descriptionThesisen_US
dc.description.abstractThis study addresses Evaluation of quality control in radiotherapy departments of the (NOC), In Sudan. The general objective was to ensure the quality of the cobalt-60(Equinox, MDS) in (RICK) and Co-60(Cirus), simulator in Al-Jazeera machines, A radiation dosimeter shall ensure that exposure minimum is normal tissue during radiotherapy and apply of QC includes minimum radiation to staff and public. To achieve that 19 QC tests were applied to CO-60(MDS, Equinox and Cirus) machines, the majority passed the following mechanical checks successfully which are: Safety interlocks control, Hand switch box, lamp indicator, Door interlock, Emergency switch, Table movement, Gantry rotation, Power supply, SSD accuracy=100cm, Treatment stop timer, Field size indicator, Audio visual monitor, Light radiation coincidence, Wedges, collimator; gantry and couch rotation isocenter. But the Co-60(Cirus) failed in rotation of couch isocenter,Lamp indicator all broken ,Laser Damage lateral damage, Co-60 (MDS) failed in laser and the Co- 60(equinox) is stopping because SSD is not functional, gantry rotation isosenter at 1800 , SSD is not functional ,laser low intensity . The Result of the 17 QC tests of simulator machine explained that this machine suffer from some problems such as Lamp light, Hand switch difficult and the stopping of Couch rotate isocenter field size error 4mm notaccepted. Finally, CO-60 (MDS) passed measurements of absorbed dose and out put constancy successfully with error 1% of the standard value.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectNuclear Physicsen_US
dc.subjectQuality Controlen_US
dc.subjectRadiotherapy Departmentsen_US
dc.subjectthe National Oncology Centersen_US
dc.titleEvaluation of Quality Control in Radiotherapy Departments of the National Oncology Centers, In Sudan for Simulator and Cobalt-60en_US
dc.title.alternativeللمحاكي تقويم ضبط الجودة في أقسامِ العلاج الاشعاعى بمراكز تحكم الاورام فى السودان والكوبالت -60en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Science

Files in This Item:
File Description SizeFormat 
Evaluation of Quality Control... .pdftitle153.43 kBAdobe PDFView/Open
Abstract.pdfAbstract115.65 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research1.96 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.