Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/28174
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abdelmageed, Nazik Mohamed Ali | - |
dc.contributor.author | Supervisor, -Abdoalrahman Hassan Ali Bakry | - |
dc.date.accessioned | 2023-02-27T08:06:08Z | - |
dc.date.available | 2023-02-27T08:06:08Z | - |
dc.date.issued | 2022-11-20 | - |
dc.identifier.citation | Abdelmageed, Nazik Mohamed Ali . Assessment of External Radiation Dose Rate after 18 Fluorodeoxyglucose Positron Emission Tomography Computed Tomography Examination \ Nazik Mohamed Ali Abdelmageed ; Abdoalrahman Hassan Ali Bakry .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2022.- 66p.:ill.;28cm.-M.Sc. | en_US |
dc.identifier.uri | https://repository.sustech.edu/handle/123456789/28174 | - |
dc.description | Thesis | en_US |
dc.description.abstract | This study was conducted to assess the external radiation dose after 18FDG-PET/CT Examination. 117 patients were enrolled in the study. Radiation exposure was measured using a calibrated RadEye SPRD-ER personal radiation detector. The measurements were made at 0, 30, 100, 150, and 200cm distance from the patient. The time of measurement was; immediately post-injection, 30 min, 60 min after injection, and at the time of releasing the patient. The result showed that the mean radiation equivalent dose rate at 0 min/0 cm was 414μSv/h, at 30 min/30 cm was 99.7μSv/h, and 60 min/100 cm was 18.3μSv/h. The radiation doses at different distances (0, 30, 100, 150, and 200cm) were 160.9μSv/h, 70.9μSv/h, 12.4μSv/h, 7μSv/h, and 3.7μSv/h respectively. In conclusion, radiation protection will be sufficient within 2 h after (18FFDG) injection for PET/CT and the radiation dose can be limited by increasing distance from the radiation source. | en_US |
dc.description.sponsorship | Sudan University of Science & Technology | en_US |
dc.language.iso | en | en_US |
dc.publisher | Sudan University of Science & Technology | en_US |
dc.subject | Medical Radiologic Sciences | en_US |
dc.subject | Nuclear Medicine Technology | en_US |
dc.subject | Radiation Dose Rate after 18 Fluorodeoxyglucose | en_US |
dc.subject | Computed Tomography Examination | en_US |
dc.subject | Positron Emission Tomography | en_US |
dc.title | Assessment of External Radiation Dose Rate after 18 Fluorodeoxyglucose Positron Emission Tomography Computed Tomography Examination | en_US |
dc.title.alternative | حقييى يعذل جزعت الإشعاع انخارجيت بعذ فحص انخصىيز ان قًطعي ان حًىسب بإ بَعاد انبىسيخزو بانفهىرودوكسي جهىكىس 18 | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Masters Dissertations : Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Assessment of External ... .pdf | Research | 690.89 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.