Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26349
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmed, Ismail Ahmed Ismail-
dc.contributor.authorSupervisor, -Abdlla Mokhtar MohammedAbdlla-
dc.date.accessioned2021-07-25T12:15:58Z-
dc.date.available2021-07-25T12:15:58Z-
dc.date.issued2020-10-22-
dc.identifier.citationAhmed, Ismail Ahmed Ismail . Increasing the Heat Transfer Efficiency of Heating System by the AdjustingFlow Rate of Thermanol/ Crude Oil : Petrodar Pipeline Case Study \ Ismail Ahmed Ismail Ahmed ; Abdlla Mokhtar MohammedAbdlla .- Khartoum: Sudan University of Science and Technology, college of Engineering and Petroleum Technology, 2020. -62p. : ill. ;28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/26349-
dc.descriptionThesisen_US
dc.description.abstractThe aim of the research is to identify the maximum efficiency of the heating system and investigate the opportunities of operating cost reduction the inPetrodaroperation company pipeline crude by adjusting thermal oil flow rate, real data (readings) such as temperature, of flow rate taken, analyzed and put into tables and graphs and calculating system efficiencywith corresponding thermail oil by excel program. The data taken for five months starting from October 2017 untilFebruary 2018.The maximum thermal efficiencywas 90.73% with lower fuel consumption 5 cubic meters per hour in December 2017, when the thermal oil flow rate (thermanol) was670315kg/ h. The appropriate fuel consumption 5 cubic meter per hours which is gives the highest crude oil temperature about 71.9 ° C. By using the finding result, we can consider it as a reference operating condition for the heating systemen_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectPetroleum Engineering & Technologyen_US
dc.subjectPetrodar Pipelineen_US
dc.subjectHeat Transfer Efficiencyen_US
dc.subjectAdjustingFlow Rateen_US
dc.subjectCrude Oilen_US
dc.titleIncreasing the Heat Transfer Efficiency of Heating System by the AdjustingFlow Rate of Thermanol/ Crude Oilen_US
dc.title.alternativeرفع كفاءة انتقال الحرارهلمنظومة التسخين من خلال ضبط معدل تدفق زيت التسخينللنفط الخامen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Petroleum Engineering & Technology

Files in This Item:
File Description SizeFormat 
Increasing the Heat .....pdfResearch2.08 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.