Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/2298
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abdulbagi, Samah Ahmed Mohammed | |
dc.contributor.author | Supervisor -Mohamed Mohamed Omer | |
dc.date.accessioned | 2013-11-14T10:35:32Z | |
dc.date.available | 2013-11-14T10:35:32Z | |
dc.date.issued | 2011-01-01 | |
dc.identifier.citation | Abdulbagi,Samah Ahmed Mohammed .Accuracy of Spiral CT Scan in Detection of Acute Pulmonary Embolism /Samah Ahmed Mohammed Abdulbagi.- Khartoum : sudan university of science and technology,Medical Radiologic Science,2011.67p. : ill ;28cm.- M.Sc. | en_US |
dc.identifier.uri | http://repository.sustech.edu/handle/123456789/2298 | |
dc.description | Thesis | en_US |
dc.description.abstract | The study aimed to determine the role of spiral CT Angiography in suspected cases of acute Pulmonary Embolism at duration (Agusust –November 2011) The study was conducted at EL-Nilien center , Royal care center and Faisal center where there were enough cases to study and the availability of required machine and materials to perform proper examination . Fifty patients of suspected pulmonary embolism (PE) of different ages and genders underwent spiral CT angiography from the level of arch of aorta to the dome of diaphragm . Scanning was done using Semince(4 multi slice) and Toshiba (64 multi slice ) machines with collimation of 1-2mm and an interval of 2mm at 60-160 mA and 120-135kV 100ml of contrast was injected at a flow rate of 3-4 ml sec with a scan delay of 12-16 second . Spiral CTA was found to be an effective method for the diagnosis of pulmonary embolism . Out of 50 patient 38 (76%) were positively identified with pulmonary embolism , more over females were most likely presented with PE . Additionally during the study , it was noted that the Rt pulmonary artery was affected more than the Lt pulmonary artery . The research confirmed that, the spiral CT scanner more acurat modality in detection of pulmonary embolism , it is non –invasive procedure , low cost , and has a high specificity , for that preferred it used as the first line of investigations in diagnosing of Pulmonary embolism . | en_US |
dc.description.sponsorship | sudan university of science and technology | en_US |
dc.language.iso | en | en_US |
dc.publisher | sudan university of science and technology | en_US |
dc.subject | Accuracy | en_US |
dc.subject | Pulmonary | en_US |
dc.title | Accuracy of Spiral CT Scan in Detection of Acute Pulmonary Embolism | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Masters Dissertations : Medical Radiologic Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Accuracy of Spiral .. .pdf | Title | 47.68 kB | Adobe PDF | View/Open |
Research .pdf | Research | 6.64 MB | Adobe PDF | View/Open |
References.pdf | References | 130.94 kB | Adobe PDF | View/Open |
Appendix.pdf | Appendix | 6.43 MB | Adobe PDF | View/Open |
Contents .pdf | Contents | 107.68 kB | Adobe PDF | View/Open |
Verse .pdf | Verse | 21.18 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.