Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/21841
Title: Effect of Roseires Dam Heightening on Thrust Bearing of the Power Generation Units
Other Titles: أثر تعلية خزان الرصيرص على كراسي إسناد وحدات محطة توليد الكهربا
Authors: Haroun, Mohammed Abdelkrim
Supervisor, - Ali Seory
Keywords: Mechanical Engineering
Power
Power Generation Units
Roseires Dam Heightening
Thrust Bearing
Issue Date: 10-Dec-2017
Publisher: Sudan University of Science and Technology
Citation: Haroun, Mohammed Abdelkrim . Effect of Roseires Dam Heightening on Thrust Bearing of the Power Generation Units / Mohammed Abdelkrim Haroun; Ali Seory .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2017 .- 86p. :ill. ;28cm .- M.Sc.
Abstract: After more than forty years without any apparent problems on their com-bined guide and thrust bearings, the seven 40 MW hydro-generators of RO-SERIS Hydroelectric Power Plant were failing. The source of the failure (which happened after heightening the dam from 40 m to 50 m) was the over heat of the thrust bearing pads. This caused considerable losses of power with high costs. The solution proposed by the operation engineers was operating the thrust bearing high pressure pumps (In case of any prob-lems with hydrodynamic lubrication- insufficient load carrying capacity- the hydrostatic jacking system been used permanently in order to increase reliability of the bearing). The direct cost was estimated to be SD 5,000,000,000 (Pumps operating and power losses).
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/21841
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Effect of Roseires....pdfResearch3.63 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.