dc.identifier.citationSaeed, Abdalla Awad Elkareem Mohammed . Study Of Lower Limbs Arteries In Diabetic Patients Using CT Angiograghy \ Abdalla Awad Elkareem Mohammed Saeed ; Hussian Ahmed Hassan .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2018.-44p.:ill.;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/21742-
dc.descriptionThesisen_US
dc.description.abstractThis study was a descriptive study type designed to study the efficacy of multi slice computerized tomography (MSCT) in imaging the lower limb arterial tree to diagnose the ischemic and other vascular disease in diabetes patient, the data was collected from radiology department of Modern Medical Center , ALMoalem Medical City , the study was carried out in the (Sudan–Khartoum state).The study duration from November 2017 to May 2018: the patient population consists of 20 females and 30 males with the mean of the ages is 65y and the male percent 60% was more than females 40%. In the study the disease prolongation categorized as (>1y, 1-5y, and<5yandpercent7.5%, 85.0%, 7.5%). And the common finding was Atherosclerosis, total stenosis; occlusion and collateral.50 diabetes patient s have undergone CT angiography of the lower limb by Multi detector (GE Optima 16 CT Scanner). with symptoms of peripheral vascular disease, All patients were scanned in the supine position with A detector configuration of 16 x .625mm is used, acquisition timing for optimum opacity is achieved by using automatic bolus tracking (Smart prep technology, GE Medical Systems), with 120-130cc of low osmolar non-ionic contrast medium (Omni opaque 300) with a flow rate between4-4.5 cc/sec, via a pressure injector, by using one box of the scan protocol. Axial images were then reconstructed with 50 percent overlap and then transferred to a dedicated workstation for 3-D reconstruction and analysis; in maximum intensity projection (MIP), volume rendered (VR) and (MPR). Our initial experience CT angiography with multi slice has clearly demonstrate efficacy as a promising new, fast, accurate, safe and non- invasive imaging modality of choice in cases of diabetes peripheral vascular diseases for diagnosis, for grading, for potential usefulness and as a treatment planning tool and are the key to communicating the findings to the treating physician, decisions making (surgical versus trans-luminal revascularization, or, intervention, conservative treatment.en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectDiagnostic Radiology Technologyen_US
dc.subjectLower Limbs Arteriesen_US
dc.subjectDiabetic Patientsen_US
dc.titleStudy Of Lower Limbs Arteries In Diabetic Patients Using CT Angiograghyen_US
dc.title.alternativeدراسه شرايين الاطراف السفلى لمرضى السكري بأستخدام أشعه الشرايين المقطعيهen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Study Of Lower Limbs ....pdfTitle91.99 kBAdobe PDFView/Open
Abastract.pdfAbstract123.59 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research2.04 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.