dc.contributor.authorMohammed, Faiza Abdelraheem Ali-
dc.contributor.authorSupervisor, -Awad Abdalla Adlan-
dc.date.accessioned2018-10-11T07:22:28Z-
dc.date.available2018-10-11T07:22:28Z-
dc.date.issued2018-01-11-
dc.identifier.citationMohammed, Faiza Abdelraheem Ali . Evaluation of Dose Calibrator Performance in Royal Care International Hospital \ Faiza Abdelraheem Ali Mohammed ; Awad Abdalla Adlan .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2018.-39p.:ill.;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/21645-
dc.descriptionThesisen_US
dc.description.abstractThis study was conducted to evaluate the performance of the dose calibrators that are used in Royal Care International Hospital (Khartoum State). The study was conducted in the nuclear medicine department in the period from July to November 2017. Quality control tests including precision, linearity, and geometrical dependency were performed using 99mTc source. To check the short term reproducibility of the dose calibrator, a standard source of 99mTc with an activity of (91 mCi) was measured ten times with a mean reading of (90.4 mCi), (±0.294). For determination of linearity 7 readings were made to standard source of 99mTc with activity of (190 mCi) at intervals up to 45 hours Geometric dependence testing was carried out by four syringes with different volumes, using standard source of Tc99m with activity of (2.60 mCi) and measured four times with a mean reading of (2.59 mCi), (±0.005). Results obtained have been compared with the international standard (±5%) and the results showed that the dose calibrator has good performance and there is no need for any correction tables or factors or maintenance for the time being.en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectCare International Hospitalen_US
dc.subjectDose Calibrator Performanceen_US
dc.titleEvaluation of Dose Calibrator Performance in Royal Care International Hospitalen_US
dc.title.alternativeتقويم أداء معايير الجرعات الإشعاعية بمستشفى رويال كير العالميةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Dose ... .pdfTitle420.54 kBAdobe PDFView/Open
Contents.pdfContents677.63 kBAdobe PDFView/Open
Abstract.pdfAbstract263.18 kBAdobe PDFView/Open
Research.pdfResearch1.08 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.