Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/21205| Title: | Study of the Scattered X-ray distributions around a Mammographic Unit |
| Other Titles: | دراسة توزيع الأشعة السينية المستطارة حول وحدة تصوير الثدي |
| Authors: | Mohamed, Hayfa Mostafa Supervisor, -Ahmed Mostafa Abukonna |
| Keywords: | Medical Radiologic Sciences Medical Physics Scattered X-ray distributions around Mammographic Unit |
| Issue Date: | 25-Jan-2018 |
| Publisher: | Sudan University of Science and Technology |
| Citation: | Mohamed, Hayfa Mostafa . Study of the Scattered X-ray distributions around a Mammographic Unit \ Hayfa Mostafa Mohamed ; Ahmed Mostafa Abukonna .- Khartoum :Sudan University of Science and Technology , Medical Radiologic Science,2018.- 49p : ill ;28 cm .- M.Sc |
| Abstract: | Mammography continues to be the primary imaging tool in the detection of early breast cancer. Because of the overall increase in the use of medical ionizing radiation, many patients and their physicians are appropriately concerned about individual radiation dose and specifically concerned about the risks of radiation from mammography. The aim of this study was to investigate scatter radiation intensity around modern digital mammography systems in three hospitals under clinical conditions. The readings were carried out using RADOS (RDS-120 Universal Survey Meter). Scatter radiation was measured at different distance in four areas around the mammography unit; these areas were the control room, Technician office, neighboring offices and Waiting area of mammography room. The distance from the mammogram and the four regions was measured. All measurements were taken in Craniocaudal projection. The result of the study showed that the readings of scattered radiation were detected in control room (0.5μSv/h) and neighboring (0.2 μSv/h) office in hospital A. It was also detected in the neighboring office (0.9 μSv/h) in hospital B, while it was noticed in the waiting area (0.8 μSv/h) in hospital C. These scatter measurements could be used in a shielding calculation and compared with current shielding design criteria to determine whether additional radiation protection or alteration to present shielding was required. |
| Description: | Thesis |
| URI: | http://repository.sustech.edu/handle/123456789/21205 |
| Appears in Collections: | Masters Dissertations : Medical Radiologic Science |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Study of the Scattered ....pdf | Titile | 39.14 kB | Adobe PDF | View/Open |
| Research.pdf | Research | 1.33 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.