dc.identifier.citationHasb ALLA, Tayseer Ismail . Finite Element Study of the Use of Reinforced Concrete Grids in Large Spans Slabs / Tayseer Ismail Hasb ALLA ; Abdelrahman Elzubeir Mohamed .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2018 .- 108p. :ill. ;28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/21124-
dc.descriptionThesisen_US
dc.description.abstractThe research reviewed the structural systems used for buildings with long spans. The use of the grid slabs for long spans was studied using the finite element method. The primary objective was to carry out a parametric study of the effect of spacing and depth of ribs for grid slabs used in long spans. A three – storeys building was selected and analyzed under dead loads using Structural Analysis Program (ETABS). The grid slabs were used as a distribution of fixed width ribs with varying spacings and the depths which were varied until suitable depth and spacing was obtained based on the results of the vertical displacements. This was considered to be the optimum grid system. A six- storeys concrete building, of known results, was then analyzed and designed using the optimum grid system (ETABS). The dead and live loads and wind loads were applied to the building and the results were checked by comparing them with published results. The comparison showed close agreement between the results. This confirmed the accuracy of the optimum grid system. The case study building was chosen as Altadamon tower (ALTBT). The steel truss system used in long spans was replaced by a concrete grid slabs system which was analyzed and designed using the optimum grid system (ETABS). The dead, live and wind loads were applied to the selected building (ALTBT). The design results were verified and checked according to BS 8110 requirements, thus confirming the correctness of the proposed grid system.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isootheren_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectConstruction Engineeringen_US
dc.subjectLarge Spans Slabsen_US
dc.subjectReinforced Concrete Gridsen_US
dc.titleFinite Element Study of the Use of Reinforced Concrete Grids in Large Spans Slabsen_US
dc.title.alternativeدراسة العنصر المحدد لإستخدام شبكيات الخرسانة المسلحة للبلاطات طويلة الأبحرen_US
dc.typeThesisen_US