Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/20367
Full metadata record
DC FieldValueLanguage
dc.contributor.authoralmonem, Mawada abd-
dc.contributor.authorSupervisor, -Hussein Ahmed Hassan-
dc.date.accessioned2018-02-20T10:40:28Z-
dc.date.available2018-02-20T10:40:28Z-
dc.date.issued2017-11-22-
dc.identifier.citationalmonem,Mawada abd.Evaluation of Radiation dose of upper limbs x-ray examination in adults\Mawada abd almonem;Hussein Ahmed Hassan.-Khartoum :Sudan University of Science and Technology , Medical Radiologic Science,2017.- 30 p : ill ;28 cm .- M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/20367-
dc.descriptionThesisen_US
dc.description.abstractThis Study was performed to evaluate radiation Entrance skin dose ESD for adults patients undergoing X-ray examination for upper limbs imaging, in two selected centers in and out Khartoum state which use Computed Radiography (CR) unit. The exposure parameters (kV, mAs and FSD) were chosen for each age category of adult from 20-70 years , then the ESD was calculated –by using the Microsoft caldose - for each category in the two hospitals and compared with the reference dose level. In center A the ESD for the upper limbs at the ages ((20-40), (40-60)) years found to be(0.54,0.47)μGy and In center B the ESD for the upper limbs the ages ((30-45),(45-60),(60-70)) years was (0.15,0.31,0.55) μGy. The final results showed that The ESD depends and changes with the exposure parameters (KV ,mAs) and changes with age. The ESD in the two centers is within the reference level and , also Variations were observed in ESD values among hospitals under study. From this study we recommended that for all x-ray equipment should be regular maintenance and quality control tests and to standardize the exposure parameters in adults imagingen_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Physicsen_US
dc.subjectlimbs x-rayen_US
dc.subjectexamination in adultsen_US
dc.titleEvaluation of Radiation dose of upper limbs x-ray examination in adultsen_US
dc.title.alternativeتقييم الجرعه الإشعاعيه للبالغين للأطراف العلويه عند التصوير الإشعاعىen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Radiation...pdf.pdfTitile953.19 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research620.17 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.