Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/19343
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmed, Soha Nagger Babiker-
dc.contributor.authorSupervisor, - Mohamed Osman Hassan-
dc.date.accessioned2017-12-11T09:40:17Z-
dc.date.available2017-12-11T09:40:17Z-
dc.date.issued2017-10-10-
dc.identifier.citationAhmed, Soha Nagger Babiker . Damping of Low-Frequency Oscillations in Inter Connected Power Systems / Soha Nagger Babiker Ahmed ; Mohamed Osman Hassan .- khartoum : Sudan University of Science and Technology, college of Engineering, 2017 .- 92p : ill ; 28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/19343-
dc.descriptionThesisen_US
dc.description.abstractStability study is the most important studies in power system; which keep the system secure and continuous operation. Stability of power system means the ability of the synchronous generators to be in synchronism when small or large disturbances occur in load or network of power system. If one of the generators losses the synchronism the other generators will be overload and make the network separate which cause blackout of the system; so that the instability problem must be solved quickly. This thesis concerned to study and analyzes the small signal, transient stability problem, and damping of low frequency oscillations by using power system stabilizer for multi machines system. The nonlinear equations which represent the system have been linearized and then placed in state space form in order to study and analysis the dynamic performance of the system. IEEE system (10 machines-39 bus bars) has been taken as case study. The AVR system causes negative damping of oscillation; so that the PSS was designed and added in optimal location by using participation factor technique to increase the damping ratio. The eigenvalue and time domain simulation methods were used to analyze the system stability; finally, the responses and results have been represented for several cases by using time domain simulation. Result obtained showed that the system without PSS is oscillatory and after add PSS to the optimal M/Cs the system return back to stability conditions after few cycles.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectPower & Machinesen_US
dc.subjectElectrical Engineeringen_US
dc.subjectPower Systemsen_US
dc.titleDamping of Low-Frequency Oscillations in Inter Connected Power Systemsen_US
dc.title.alternativeتخميد ترددات التذبذبات المنخفضة في انظمة القدرة المترابطة داخلياen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Damping of Low-Frequency....pdfResearch3.7 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.