Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/18859
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmed, Mugtaba Nour Eldaim Mohammed-
dc.contributor.authorSupervisor, - Eihab Abd Alrouf Mustafa-
dc.date.accessioned2017-10-23T08:39:20Z-
dc.date.available2017-10-23T08:39:20Z-
dc.date.issued2017-08-10-
dc.identifier.citationAhmed, Mugtaba Nour Eldaim Mohammed . Preparing a Computer Program to Evaluate the Performance of Garri Combined Cycle Power Plant / Mugtaba Nour Eldaim Mohammed Ahmed ; Eihab Abd Alrouf Mustafa .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2017 .- 99p. : ill. ;28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/18859-
dc.descriptionThesisen_US
dc.description.abstractThis study looking for benefit possibility of computer device in Garri Combined Cycle 1&2 thermal power generation to improve performance of plants . The researcher developed the program by MATLAB using GUI to evaluate performance and status of the plants . It is content main interface and status interface . Main interface content empty texts boxes to enter the data . Primary data must be entered at first time (primary value selection) and daily data then press calculate . After first time daily data just should be entered by user . when calculate has been pressed some tables should be appeared . Station power generation table , it’s content power generated , power factor generation , power auxiliary consumption , planned energy losses , unplanned energy losses and availability for each machine . Also resources consumption and supply table , it’s content LDO and HCGO fuel consumption for each machine , total pump able fuel stock in tanks , total fuel stock ,river side supply water , and demin water quantity for each plant . Also units availability and remarks table , it’s content availability , status and last power generated recorded . Also specific fuel consumption table and efficiency table for each machine . Status interface content empty texts boxes for plant one and plant two to enter daily power generated in each hour to get graphics show user status of each machine .en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMechanical Engineeringen_US
dc.subjectCycle Power Planten_US
dc.subjectGarri Combineden_US
dc.subjectComputer Programen_US
dc.titlePreparing a Computer Program to Evaluate the Performance of Garri Combined Cycle Power Planten_US
dc.title.alternativeإعداد برنامج حاسوبي لتقويم أداء محطة قري ذات الدورة المشتركةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Preparing a Computer Program ....pdfResearch2.54 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.