| dc.identifier.citation | Elsmani, Ahmed Elazrag Zein Elabdeen . Quantifying the Cost of Unplanned Outage at Khartoum North Thermal Power Station / Ahmed Elazrag Zein Elabdeen Elsmani ; Eihab Abdelraouf Mustafa .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2017 .- 104p. : ill. ;28cm .- M.Sc. | en_US |
| dc.identifier.uri | http://repository.sustech.edu/handle/123456789/18840 | - |
| dc.description | Thesis | en_US |
| dc.description.abstract | This research concerns with the energy resources in Sudan. It includes the steam plants, their unplanned outage problems. The study conducted on Dr. Sharief power station in Khartoum north. The research is studied the station problems occurring during the period (Jan 2011 to Dec 2015), the maintenance program procedure and management method description. Losses resulting from unplanned outage were calculated. The rest of maintenance was not calculated because there were no enough data about material at the time in the unplanned outage case, communication, cleaning, lubrication and transportation. In conclusion recommendations to prevention or reduction in the unplanned outage has been represented, station should also be rehabilitated, this will improve the station efficiency. | en_US |
| dc.description.sponsorship | Sudan University of Science and Technology | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Sudan University of Science and Technology | en_US |
| dc.subject | Power Engineering | en_US |
| dc.subject | Mechanical Engineering | en_US |
| dc.subject | Quantifying the Cost of Unplanned Outage | en_US |
| dc.title | Quantifying the Cost of Unplanned Outage at Khartoum North Thermal Power Station | en_US |
| dc.title.alternative | حساب تكاليف توقف محطة الخرطوم بحري الحرارية الغير مبرمج | en_US |
| dc.type | Thesis | en_US |
| Appears in Collections: | Masters Dissertations : Engineering | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Quantifying the Cost of Unplanned ....pdf | Research | 3.2 MB | Adobe PDF | View/Open |
| Quantifying the Cost of Unplanned ....pdf | Title | 3.2 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.