Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/18357
Title: Investigating the Attenuation Coefficient for Different Material using X-Ray and Gamma Ray
Other Titles: التحقق من معامل التوهين لمواد مختلفة باستخدام الاشعة السينية واشعة قاما
Authors: Mohammed, Ammar Adam
Supervisor, - Ahmed Al-Hassan Al-Faki
Keywords: Physics
Gamma Ray
X-Ray
Attenuation Coefficient
Issue Date: 10-May-2017
Publisher: Sudan University of Science and Technology
Citation: Mohammed, Ammar Adam . Investigating the Attenuation Coefficient for Different Material using X-Ray and Gamma Ray / Ammar Adam Mohammed ; Ahmed Al-Hassan Al-Faki .- Khartoum: Sudan University of Science and Technology, college of Science, 2017 .- 65p. :ill. ;28cm .- M.Sc.
Abstract: In this research two different source were used with different material in order to investigate the attenuation of x-ray and Gamma- ray as function of the absorber thickness and to compare the effect of this source in attenuation coefficient and to verify Lambert’t law of attenuation. It was found that the attenuation coefficient for X-ray is greater than Gamma ray. It was also found attenuation coefficient of X-ray for Cu is equals 11.7, Fe is equals 6.82 and Al is equals 1.2. The attenuation coefficient of Gamma ray for Cu is equals 0.103, Fe is equals 0.687 and Al is equals 0.0235. Thus Cu is best shielding compared to Fe and Al.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/18357
Appears in Collections:Masters Dissertations : Science

Files in This Item:
File Description SizeFormat 
Investigating the Attenuation Coefficient ....pdfTitel169.66 kBAdobe PDFView/Open
Abstract.pdfAbstract312.34 kBAdobe PDFView/Open
Research.pdfResearch1.1 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.