dc.identifier.citationELGORAESH, SIDDIG ADAM BABIKIR . Evaluation Of Image Quality For Emergency Traumatic Patients \ SIDDIG ADAM BABIKIR ELGORAESH ; MOHAMED MOHAMED OMER M.YOUSEF .- Khartoum:Sudan University of Sciences and Technology,Medical Radiographic Sciences,2016.-63p:ill;28cm.- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/16801
dc.descriptionThesisen_US
dc.description.abstractObjective: is to apply a technical protocol to reduce CT radiation Dose in trauma cases by decreasing the mA (tube current). The target reduction is 50%. Method: Performing scanning on an adult phantom for trauma protocol Brain. Reference scan (default exposure) 300mA to be registered In exposure log shoot and calculate the dose received in msv. Scan2 reducing mA to200 and registered the dose, evaluate the Image quality.scan 3 reducing mA to100 and registered the dose Received, evaluate the image .phase (2)implemented if phantom Image quality is of acceptable quality .Performing CT trauma with The default exposure parameters and register the dose received . Reference scan can be obtained from previous CT trauma cases. Performing CT trauma with reduction of mA factor to 200mA and Registering the dose received image to be evaluated by the tech- -nologist and radiologist. Performing CT trauma with reduction of mA factor to 100mA and register the dose received .Image also to be evaluated by the technologist and radiologist .Applying the rec- -commendations CT technologists and radiologists on the range of Accepted quality and delineate the reduction rate. CT trauma cases with reduced mA can be viewed and the review The radiologist reports . Reduction of mA factor in CT parameters will induce reduction in CT dose to the patient and this can be applied to all cases. Performed scan for 54 cases 28 cases with tube current 200 mA And 26 cases with tube current 100 mA .The result was found Clearly the absorbed dose and the effective dose fall down to the Half when used 200mA and more less when we used 100mA as tube current .en_US
dc.description.sponsorshipSudan University of Sciences and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectDiagnostic Radiologic Technologyen_US
dc.subjectImage Qualityen_US
dc.subjectEmergency Traumatic Patientsen_US
dc.titleEvaluation Of Image Quality For Emergency Traumatic Patientsen_US
dc.title.alternativeتقييم جودة صور الأشعة لمرضى اصابات الطواريen_US
dc.typeThesisen_US
dc.contributor.SupervisorSupervisor,- YOUSEF, MOHAMED MOHAMED OMER M.
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation Of Image ... .pdfTitle150.04 kBAdobe PDFView/Open
ABSTRACT.pdfAbstract590.74 kBAdobe PDFView/Open
Research.pdfResearch2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.