Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/16122
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAWED, TAGHREAD SALAH
dc.date.accessioned2017-04-18T06:06:33Z
dc.date.available2017-04-18T06:06:33Z
dc.date.issued2017-02-23
dc.identifier.citationAWED, TAGHREAD SALAH . Assessment of Glomerular Filtration Rate in Diabetic and Hypertensive Patient using Scintigraphy \ TAGHREAD SALAH AWED ; MOHAMMED ELFADEL MOHAMMED .- Khartoum:Sudan University of Science & Technology,Medical Radiographic Sciences,2017.-66 p.:ill.;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/16122
dc.descriptionThesisen_US
dc.description.abstractThis study was aimed to calculate the GFR in patient whom had diabetic mellitus and hypertensive disease to show how it effecting the GFR. Analytical study designed and conducted in the nuclear medicine department at fedil hospital, in the period from September to December (2016). The data were collected from 35 patients with renal problem where 15 were diagnosis as normal GFR patient, 10 of them were diagnosis as diabetic patient, and 10 were diagnosis as hypertensive patient. Tc99m-DTPA was administrating to the patient intravenously and Gamma camera (SPECT MULTICAM 2000”) was used to detect the count and hence GFR were calculated. The result showed that the uptake phase co-offecient for hypertensive was decrease by 6.17cont /second while uptake phase co-offecient for diabetic was decrease by 3.743 cont /second, that meaning the effect of hypertensive is more than that of diabetic. In conclusions we found there is significant difference in absorption co-offecient phase between normal and abnormal (hypertensive and diabetic) one which equal 0.007and 0.013at probability p=0.05 in hypertensive and diabetic with normal respectively done by t-test. On the other hand the secretion phase inconclusive difference these due to the hypertension and diabetic have no direct effect on secretion phase, it function of renal tubule not direct effect thought the blood vessels.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectNuclear Medicineen_US
dc.subjectGlomerular Filtrationen_US
dc.subjectRate in Diabeticen_US
dc.subjectHypertensive Patienten_US
dc.subjectScintigraphyen_US
dc.titleAssessment of Glomerular Filtration Rate in Diabetic and Hypertensive Patient using Scintigraphyen_US
dc.title.alternativeتقويم معدل الترشيح الكبيبي لدي مرضي السكري وارتفاع ضغط الدم باستخدام النظائر المشعةen_US
dc.typeThesisen_US
dc.contributor.SupervisorSupervisor,- MOHAMMED ELFADEL MOHAMMED
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Glomerular ....pdfResearch2.6 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.