Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/16121
Title: Measurement of Normal Diameter of Thoracic Aorta using Computed Tomography
Other Titles: قياس الشريان الأبهر الصدري للسودانيين بإستخدام الأشعة المقطعية المحوسبة
Authors: Saad, Amgad Yousif Babiker
Supervisor,- Asma Ibrahim Ahmed Elameen
Keywords: Medical Radiologic Sciences
Diagnostic Radiologic Technology
Normal Diameter
Thoracic Aorta
Issue Date: 9-Feb-2017
Publisher: Sudan University of Science and Technology
Citation: Saad, Amgad Yousif Babiker . Measurement of Normal Diameter of Thoracic Aorta using Computed Tomography \ Amgad Yousif Babiker Saad ; Asma Ibrahim Ahmed Elameen .- Khartoum:Sudan University of Science & Technology,Medical Radiographic Sciences,2017.-70p.:ill.;28cm.-M.Sc.
Abstract: This is a cross sectional descriptive study, deals with measurement of normal diameter of the thoracic aorta in Sudanese population. The study conducted at computed tomography departments of Alribat National hospital , Alamal National hospital diagnostic center and Doctor’s spthalized hospital. A 50 cases were selected randomly, The patients are not suffering from any pathological condition concerning the thoracic aorta. This study used the tools of computed tomography to measure the normal diameter of the descending thoracic aorta. The data designed to include the specific variables for the patients and were analyzed by SPSS program. The mean Length of the thoracic Aorta was 14.71±2.67 cm, The Proximal width of Aorta was 2.51±0.56 cm, the middle width of Aorta was 2.08±0.41 cm, the distal width of Aorta was 2.11±0.45 cm. The height and weight of the patient has showed no significant difference with the aorta diameter than the other variable (p-value is 0.000) respectively. Also highly significant difference (P=0.001) was detected between age and distal width of aorta, but low significant difference (P=0.018) was obtained between the height of the patient and distal width of Aorta. Also lower significant difference (P=0.015) was noticed between weight of the patient and distal width of Aorta. the study concluded that computed tomography is play a great role in the measurement of normal diameter of descending of thoracic aorta
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/16121
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Measurement of Normal ... .pdfResearch2.1 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.