Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/15908
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTaha, Esra Taha Ali
dc.contributor.authorSupervisor,- Zeinab Adam Mostafa
dc.date.accessioned2017-03-28T07:55:38Z
dc.date.available2017-03-28T07:55:38Z
dc.date.issued2017-01-10
dc.identifier.citationTaha, Esra Taha Ali . Dialysis Solution Analysis forPeritonitis Infection Prevention by usingOptical System Prototype / Esra Taha Ali Taha ; Zeinab Adam Mostafa .- Khartoum: Sudan University of Science and Technology, college of Engineering, 2017 .- 114p. :ill. ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/15908
dc.descriptionThesisen_US
dc.description.abstractContinuous Ambulatory Peritoneal Dialysis CAPD peritonitis usually occurs due to contamination by bacteria from the skin or the environment of the inserted catheter,peritonitis infection isan important cause of CAPD failure and patients switching to another treatment, it has many signs the predominant one is a cloudy bag, this research used the cloudy bag sign to detect the infection inan early stage. The aim of this study was to analyze dialysis solution for peritonitis infection prevention by designing a simple prototype to detect the turbid solution by using Scattering Light Theory.This study was applied on 14 patients (male and female) with different ages. Two samples were taken from the patients one was reading at the same time,the second was sub culturing by standard bacteriato simulate the peritonitis infection proportion to the difficulty of finding peritonitis infection samples. 180 known samples were detected by the prototype 90 samples with bacteria and 90 without bacteria to determine the range of normal and abnormal. The inverse relationship where the greater dispersion of light (increased turbidity) the less resistance valuein the examined samples .The classification function was produced and gave result with the normal and infected sample with accuracy equal to (70.9%). The prototype reading was compared with laboratory turbidimeter on National Public Health Laboratory (STAC) and gave satisfied results.Optical system is a simple way for turbidity detection, help old and new patient to detect the peritonitis infection in an early stage.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectOptical System Prototypeen_US
dc.subjectDialysis Solution Analysisen_US
dc.subjectforPeritonitis Infection Preventionen_US
dc.titleDialysis Solution Analysis forPeritonitis Infection Prevention by usingOptical System Prototypeen_US
dc.title.alternativeتحليل محلول الغسيل الكلوي للوقاية من الالتهاب البرتوني باستخدام نموذج النظام الضوئىen_US