Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/15799
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohammed, Waleed Elatta Mahmoud-
dc.contributor.authorSupervisor, - Mohamed Elfadil Mohamed Gar Elnabi-
dc.date.accessioned2017-03-19T11:48:24Z-
dc.date.available2017-03-19T11:48:24Z-
dc.date.issued2017-02-27-
dc.identifier.citationMohammed, Waleed Elatta Mahmoud . Estimation of Radiation Dose to Eye Lens for the Patients Undergoing Scan of Brain by Computed Tomography \ Waleed Elatta Mahmoud Mohammed ; Mohamed Elfadil Mohamed Gar Elnabi .- Kartoum:Sudan University of Science and Technology,Medical Radiologic Sciences,2017 .- 48p:ill;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/15799-
dc.descriptionThesisen_US
dc.description.abstractThe aim of this study to estimation the radiation dose for eye lens for patients underwent thescan head by CT model of Toshiba 64 slices in the (RCIH,ANH and ZSH). The data collected from 51patient in three hospitals, Data were used to estimation and comparing the Equivalent dose of eye lens from different diagnostic procedures in three hospitals with the other study from deferent country. was used CT-Exposoftware Version 2.5 for dose calculations, the effective dose between the all hospital in this study, the small value of Effective dose in RCIH (3.92 mSv) then ANH (4.64 mSv) and higher dose in ZSH (5.34 mSv) and higher than the study in Tanzania (2.1 mSv), Australia (3.61 mSv) and UK (1.5 mSv), the Equivalent dose of eye lens is small dose in RCIH (82.97 mSv), then ANH (88.61 mSv) and higher dose in ZSH (97.01 mSv), Themean CTDIVOL values in hospitals is higher than similar study in other country example as (UK (55-65 mGy), Sudan (65.4 mGy) and Tanzania (43 mGy)), except the Australia (86.7 mGy), DLP values was found in this study were higher (1547.5 mGy*cm) than those presentedin Tanzania (913 mGy*cm), Australia (1508.4 mGy*cm) and UK (760-930 mGy*cm).en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectRadiation Doseen_US
dc.subjectEye Lensen_US
dc.subjectComputed Tomographyen_US
dc.titleEstimation of Radiation Dose to Eye Lens for the Patients Undergoing Scan of Brain by Computed Tomographyen_US
dc.title.alternativeتقدير الجرعة الإشعاعية لعدسة العين للمرضى الذين يخضعون لتصويرالدماغ عن طريق التصوير المقطعيen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Estimation of Radiation ... .pdfResearch1.44 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.