Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/15716
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohammed, Ayat Elnour Ahmed
dc.contributor.authorSupervisor, - Ikhlas Abdelaziz Hassan
dc.date.accessioned2017-03-08T12:24:52Z
dc.date.available2017-03-08T12:24:52Z
dc.date.issued2016-11-09
dc.identifier.citationMohammed, Ayat Elnour Ahmed . Evaluation ofNormal Amniotic Fluid Volume in third Trimester Using Ultrasonography \ Ayat Elnour Ahmed Mohammed ; Ikhlas Abdelaziz Hassan .- Kartoum:Sudan University of Science and Technology,Medical Radiologic Sciences,2016.-56p:ill;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/15716
dc.descriptionThesisen_US
dc.description.abstractThe study was carried out to assess the amniotic fluid volumein third trimester by ultrasound in Sudanese patients at Khartoum state-Sudan in Elrakha hospital,Elsoudy hospital andAhfad family health center in period fromMarch to October 2016. The study aimed to identify normal value of amniotic fluid in Sudanese pregnant ladies in third trimester and to correlate gestational age with amniotic fluid volume in Sudanese pregnant ladies. The study concluded several results including, found most of Sudanese pregnant ladies have normal amniotic fluid 96% and few pregnant ladies have abnormal amniotic fluid 4%. The study reviewed the international studies of normal amniotic fluid volume in different countries and found that the amniotic fluid volume is different from population to population due to environment, maternal size and intrauterine volume and not have constant value. The study recommended that assessment of amniotic fluid volume by ultrasound is an essential parameter of antenatal care.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectUltrasonographyen_US
dc.subjectEvaluation ofNormal Amnioticen_US
dc.titleEvaluation ofNormal Amniotic Fluid Volume in third Trimester Using Ultrasonographyen_US
dc.title.alternativeتقويم الحجم الطبيعي للسائل الامنيوني في الثلث الاخير للحمل باستخدام الموجات فوق الصوتيةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation ofNormal .... .pdfResearch999.88 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.