Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/1517
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGalal, Sara Saadeldein
dc.contributor.authorSupervisor-Mohamed Elfadil
dc.date.accessioned2013-09-11T13:15:42Z
dc.date.available2013-09-11T13:15:42Z
dc.date.issued2013-02-01
dc.identifier.citationGalal,Sara Saadeldein .Optimization of Exposure Factor For planner lateral Skull Radiograph/Sara Saadeldein Galal; Mohamed Elfadil .- Khartoum : sudan university of scince and technology, Medical Radiologic scince ,2013 .- 57p. : ill ;28cm . -M.sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/1517
dc.descriptionThesisen_US
dc.description.abstractCT scan is play important role in diagnostic radiology and valuable in Sudan have amore advantage like study of sectional anatomy, evaluate the texture of soft tissue, three damnation imaging and fast sequence examination. The aim of This study intended to measurement the retrosternal goiter mass, level of extension and texture of mass. Random samples consist of 22 patients who underwent CT scan for chest or neck examination. The patients IX were registered (age, gender, HU, AP diameter, right to left diameter, texture of mass and extension) . Out of this sample,15(68%) patients were females while the 7(32%) were males and their ages ranged from 20 to 80 years old. The study was done in – ( Royal care) and (Khartoum teaching hospital) hospital-Khartoum. The study finding mean CT number was 119.2±24.2 and the range was 97 to 163 HU for middle level per procedure, The mean of AP diameter in middle level 59.2±13.5 mm and rang 37 to 91 , The mean of Right to lift diameter in middle level is about 50.2±18.5 mm and rang 19 to 86, the most texture are calcified and the extension level in most patient C4-5 to T4-5. The study shows measurement of retrosternal goiter for this study were smaller than the most previous study.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of scince and technologyen_US
dc.subjectplanner Lateral skull-imagingen_US
dc.titleOptimization of Exposure Factor For planner lateral Skull Radiographen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Optimization of Exposure...pdfTitle269.23 kBAdobe PDFView/Open
Abstract.pdfAbstract357.68 kBAdobe PDFView/Open
Research.pdf
  Restricted Access
Research15.08 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.