Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/15031
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohammed, Hozyfa Ahmed Hamdan-
dc.contributor.authorSupervisor, Ahmed Elsadig Mohammed Saeed-
dc.date.accessioned2016-12-26T09:58:52Z-
dc.date.available2016-12-26T09:58:52Z-
dc.date.issued2016-10-19-
dc.identifier.citationMohammed, Hozyfa Ahmed Hamdan . Development and Validation of Two UV Spectrophotometric and High Performance Liquid Chromatography Assay Methods of spironolactone / Hozyfa Ahmed Hamdan Mohammed ; Ahmed Elsadig Mohammed Saeed .- Khartoum: Sudan University of Science and Technology, college of Science, 2016 .- 63p. :ill. ;28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/15031-
dc.descriptionThesisen_US
dc.description.abstractIn this work simple, precise and accurate spectrophotometric and high performance liquid chromatography (HPLC) assay methods for spironolactone in raw material and tablet dosage form were developed and validated. HPLC analysis method was developed using inertstil C18 (250 *4.6 mm), 5μm column with a mobile phase consisting of phosphate buffer solution pH = 4 and acetonitrile in (1:1) ratio. The flow rate was adjusted at 1.5 ml/min, detection wavelength, at 240 nm, temperature, at 40 ᵒC and retention time was found to be 4.5 min. In spectrophotometric analytical method, two methods in UV region were developed and validated as Hydrazine and Hydroxylamine methods. The maximum absorption wavelength for determination of spironolactone was found to be 236.8 nm, but those for Hydrazine and Hydroxylamine derivatization were found to be 251.5 nm and 263.7 nm, respectively. Beer’s law was obeyed in the concentration range from 20 ppm to 30 ppm for both HPLC and spectrophotometric analysis methods. The assay percentage (mean ±RSD) for tablet commercial formulation was found to be (98.00±0.39) %, (97.15±0.28) % and (98.25±0.59) % for Hydrazine, Hydroxylamine and HPLC methods, respectively. The percentage of recovery was found to be (100.20-102.65) %, (98.47-100.67) % and (99.40-101.99) % for Hydrazine, Hydroxylamine and HPLC methods, respectively. The limit of detection (LOD), however, was found to be in the range from 0.028 ppm to 0.553 ppm for all methods. The limit of quantitation (LOQ) was also found to be in the range from 0.086 ppm to 1.677 ppm for all methods. All the validation methods were carried out according to ICH Q2 (R1) guideline.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectChemistryen_US
dc.subjectAssay Methods of spironolactoneen_US
dc.subjectLiquid Chromatographyen_US
dc.subjectSpectrophotometricen_US
dc.titleDevelopment and Validation of Two UV Spectrophotometric and High Performance Liquid Chromatography Assay Methods of spironolactoneen_US
dc.title.alternativeتطوير و تحقيق صلاحية طريقتين مضوائيتين طيفيتين ل لاشعة فوق البنفسجية و طريقة كروماتوغرافيا الأداء العالي لتحليل ا لسبيرونولكتونen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Science

Files in This Item:
File Description SizeFormat 
Development and Validation... .pdfTitel237.36 kBAdobe PDFView/Open
Abstract.pdfAbstrct571.13 kBAdobe PDFView/Open
Research.pdfResearch3.79 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.