Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/14370
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohamed, Sanaa Ali
dc.contributor.authorSupervisor,- Hussein Ahmed Hassan
dc.date.accessioned2016-10-24T09:48:23Z
dc.date.available2016-10-24T09:48:23Z
dc.date.issued2016-08-18
dc.identifier.citationMohamed, Sanaa Ali.Assessment of Effect dose in CT renal Angiography/Sanaa Ali Mohamed;Hussein Ahmed Hassan.-Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Sciences,2016.-84p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/14370
dc.descriptionThesisen_US
dc.description.abstractComputed Tomography (CT) is diagnostic imaging modality giving higher patient dose in comparison with other radiologic procedures, so the calculation of patient dose in CT exam is very significant . CT improved many diagnoses of diseases. The increasing use of CT in Sudan in recent years is consider to motivated the researchers to reduce the exposure of the patient dose and that the risks Known to X-ray. This study aimed to assessing the radiation dose and estimating the risks resulting from exposure to X-ray during CT angiography (CTA) the 64 slice instruments . A total of 50 patient were examined in Alamal National hospital and AlBugaa Diagnostic hospital using spiral CT Scan 64 slices and general electric 16 slices (in the period April 2016-May 2016) The average age of patient samples was(46.4000±14.02621)Years .The main effective dose of renal angiography per procedure was (4.4741±1.28744) msv.The patient will exposed to standard dose during the examine of renal CT angiography .The measurement of the dose during renal procedure can be considered as the best method of evaluation of the cancer risksen_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectAssessment of Effect doseen_US
dc.subjectrenal Angiographyen_US
dc.titleAssessment of Effect dose in CT renal Angiographyen_US
dc.title.alternativeتقييم الجرعة المؤثرة اثناء تصويرالاوعية الكلوية بالاشعة المقطعيةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Effect.....pdfResearch519.49 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.