dc.identifier.citationMohieldein, Siddig Abuelgasim Abbas . Exergy Analysis of Combined Cycle Power Plant (GARRI”2” 180 MW) / Siddig Abuelgasim Abbas Mohieldein ; A. A. A.Abuelnour ; Khartoum: Sudan University of Science and Technology, college of Engineering, 2016 .- 71p. :ill ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/14292
dc.descriptionThesisen_US
dc.description.abstractIn recent years the entire world is a warring about energy resources limitation, specifically Sudan country confronts critical crises in fossil fuel resources and yet more of electricity energy producing from fired thermal power plants. One from these plants Garri”2” combined cycle producing about 180MW. Exergy analysis in the light second law of thermodynamics is powerful tools to investigate from optimization of engineering devices. Exergy analysis has been carried out analytically for Garri”2” to evaluate exergetic efficiency and exergy destruction of each part; exergy balance and entropy generation calculated to achieve it .The results showed that combustion chambers are the main sources of exergy destruction due to high irreversibilities representing 63% from total exergy destruction, followed by gas turbines 13.6%, steam turbines 6.4%, heat recovery steam generators(HRSGs) 6.3%, stacks (exhaust gases) 4.7%, compressors 3.8% and cooling systems 2.3%. The results also showed that thermal and exergetic efficiencies for entire plant are (38%, 49%) respectively.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectmechanical engineeringen_US
dc.subjectpoweren_US
dc.subjectAlaksergee analysisen_US
dc.subjectPower planten_US
dc.titleExergy Analysis of Combined Cycle Power Plant (GARRI”2” 180 MW)en_US
dc.title.alternativeتحليل الإكسيرجي للدورة المشتركة في محطة الطاقة قري(2)(180MW)en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Exergy Analysis of... .pdfResearch14.48 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.