Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/13812
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElbashier, Mona Elsafi Massaad
dc.contributor.authorSupervisor,- Hussein Ahmed Hassan
dc.date.accessioned2016-07-20T07:18:53Z
dc.date.available2016-07-20T07:18:53Z
dc.date.issued2016-04-27
dc.identifier.citationElbashier, Mona Elsafi Massaad. Evaluation of Patient Dose in Conventional Chest and lumbar spine X-Ray using Skin Estimated Dose/Mona Elsafi Massaad Elbashier;Hussein Ahmed Hassan.-Khartoum:Sudan University of Science and Technology,College Radiologic Sciences,2016.-55p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/13812
dc.descriptionThesisen_US
dc.description.abstractThis study aims to evaluate of patient radiation dose in chest x-ray using Entrance surface dose calculations, the study was done in two hospitals Alshab Teaching Hospital and Ibrahim Malik Teaching Hospital in Khartoum state, Entrance surface dose (ESD) was determined from exposure settings and patient information using mathematical equation . 220 patients were examined in this study, The entrance surface doses (ESDs) to patient undergoing chest X-ray radiography Exposure settings and patients data were recorded. Result concerning the kilovoltage (KVp) and tube current (mAs) and focus to film distance (FFD) settings. The variation in the patient doses and techniques used for the examinations studied were found among the different hospitals denoting the importance of establishing a national quality assurance programme and examination protocols to ensure patient doses are kept as Low as possible. Mean ESDs obtained for chest radiography in Alshab Teaching Hospital recorded in this study was ( .125 +0.04) mGy and Mean ESDs obtained for Lumbar spine radiography in Ibrahim Malik Teaching Hospital recorded in this study was (4.39 +1.23) mGy.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectRadiologic Medical Sciencesen_US
dc.subjectConventional Chesten_US
dc.subjectlumbar spineen_US
dc.titleEvaluation of Patient Dose in Conventional Chest and lumbar spine X-Ray using Skin Estimated Dose.en_US
dc.title.alternativeتقييم جرعة المريض في تصوير الصدر والعمود الفقري في جهاز الأشعة السينية التقليدي باستخدام جرعة السطح المقدرةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Patient....PDFTitle200.99 kBAdobe PDFView/Open
Abstract.PDFAbstract627.7 kBAdobe PDFView/Open
Research.PDFResearch1.6 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.