Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/13773
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAli, Tagwa Ali Almaki
dc.contributor.authorSupervisor,-Awadh Abdallah Adlan Jamie
dc.date.accessioned2016-07-19T07:00:09Z
dc.date.available2016-07-19T07:00:09Z
dc.date.issued2016-04-07
dc.identifier.citationAli, Tagwa Ali Almaki.Evaluation of Performance of the SPECT Camera in Elnilien Medical Diagnostic Centre in Khartoum/Tagwa Ali Almaki Ali;Awadh Abdallah Adlan Jamie .-Khartoum:Sudan University of Science and Technology,College Radiologic Sciences2016.-63p:ill;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/13773
dc.descriptionThesisen_US
dc.description.abstractThe objective of this study is to evaluate the performance of the SPECT gamma camera at Alnilien Medical Diagnostic Centre of Khartoum. This study was carried out in Nuclear Medicine Department in Alnelein Medical Diagnostic Centre (NMDC) and the results were compared with the international guidelines. The study evaluates the following parameters: energy resolution, uniformity, sensitivity and linearity. All results that obtained from the study have been compared with the acceptance limits with IAEA and NEMA -2001 standards. The results reveal that the energy resolution showed a central peak of the energy at 140KVp and the value of the energy resolution was 7.6%. Also results showed that the average of differential uniformity was 3.4% and it was within the acceptable value, and the integral uniformity was 1.94%. Also the results showed that the average of sensitivity was 83.4cpm/MBq , and the results reveal the average linearity value of 1.3mm that detect distortion of linearity due to X and Y positions do not change linearly with displacement distance of radiation source across the face of the detector. The quality of medical images was high and provides good care of patients. A regular quality assurance tests improve quality management of nuclear medicine imaging.en_US
dc.description.sponsorshipSudan University of science and technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectRadiologic Medical Sciencesen_US
dc.subjectEvaluation of Performanceen_US
dc.subjectMedical Diagnostic Centreen_US
dc.titleEvaluation of Performance of the SPECT Camera in Elnilien Medical Diagnostic Centre in Khartoumen_US
dc.title.alternativeتقويم أداء جهاز قاما كاميرا للأشعة المقطعية المحوسب بمركز النيلين التشخيصي بالخرطومen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Evaluation of Performance ....pdfResearch1.37 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.