Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/13647
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElfadil, Mawada Mohammed
dc.contributor.authorSupervised,- salah Ali Fadlalla
dc.date.accessioned2016-06-13T06:57:18Z
dc.date.available2016-06-13T06:57:18Z
dc.date.issued2016-06-03
dc.identifier.citationElfadil, Mawada Mohammed.Assessment of Radiation Dose Calibrator Performance in the Nuclear Medicine Department of the National Cancer Institute Wad Madani/Mawada Mohammed Elfadil; salah Ali Fadlalla.-Khartoum:Sudan University of Science and Technology,College Radiologic Sciences,2016.-87p:ill;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/13647
dc.descriptionThesisen_US
dc.description.abstractNuclear medicine uses many different radioactive isotopes for radiation diagnostic studies and for therapy . The amounts of radioactivity has to be determined exactly before it is applied to patients. The dose calibrator has to measure the radioactivity of gamma and beta with different energies precisely for high quality imaging and for applying the right amount of radiation to have good images which give good diagnosis and effective treatment of diseases . This study was carried out to assess the performance of dose calibrator which is used in nuclear medicine in the National Cancer Institute –wad madani (Gazera state) . The study period was from October 2015 to February 2016 . Four quality control tests were carried out using standard radionuclide , 137Cs . The tests included accuracy ,constancy ,linearity and Geometry .All results that were obtained from the study were compared with the international standard (±5%) and the results showed that the dose calibrator under the study was of good performance and there is no need for any correction tables or factors or maintenance for the time being. This study was carried out to assess the performance of dose calibrator which is used in nuclear medicine in the National Cancer Institute –wad madani (Gazera state) . The study period was from October 2015 to February 2016 . Four quality control tests were carried out using standard radionuclide , 137Cs . The tests included accuracy ,constancy ,linearity and Geometry .All results that were obtained from the study were compared with the international standard (±5%) and the results showed that the dose calibrator under the study was of good performance and there is no need for any correction tables or factors or maintenance for the time being.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectRadiologic Medical Sciencesen_US
dc.subjectradioactive isotopesen_US
dc.subjectradioactivityen_US
dc.titleAssessment of Radiation Dose Calibrator Performance in the Nuclear Medicine Department of the National Cancer Institute –Wad Madanien_US
dc.title.alternativeتقدير أداء جهاز قياس الجرعات الإشعاعية بقسم الطب النووي بالمعهد القومي للسرطان - ود مدنيen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Radiation .....pdfResearch1.44 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.