Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11985
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAli, Bekhita Alamin Hamed-
dc.contributor.authorSupervisor,- Mubarak ELsaeed Mustafa Elkarsani-
dc.date.accessioned2015-11-22T11:37:45Z-
dc.date.available2015-11-22T11:37:45Z-
dc.date.issued2015-07-01-
dc.identifier.citationAli,Bekhita Alamin Hamed.Assessment of Quality Parameters of Platelets Concentrated Prepared at ElmekNimer University Hospital Blood Bank-ShendiCity/Bekhita Alamin Hamed Ali;Mubarak ELsaeed Mustafa Elkarsani.-Khartoum:Sudan University of Science and Technology,Medical Laboratory Science,2015,75p.:ill.;28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11985-
dc.descriptionThesisen_US
dc.description.abstractThis study is a descriptive and analytical prospective cross-sectional study conducted in the period from February to April 2015 to assess the quality parameters of platelet concentrates prepared at Elmek Nimer University Hospital Blood Bank. Fifty Platelet concentrate units were prepared from whole blood using the platelet-rich plasma method. All units were stored at 22-2 ˚C on a flatbed agitator for five days. Platelet quality parametersincluding the platelet count, volume of the platelet concentrate, swirling, residual white blood cells, red blood cells and pH were assessed on day one and day five. The results revealed that the mean platelet concentrate volume was 72.06±10.42 ml and ranged from 50-93 mlVs a mean of 68.06±10.42 ml and range from 46-89 ml, the mean platelet count was 5.09±1.51x1010/Unit and ranged from 2.2-9.9x1010/Unit Vs a mean of 4.50±1.46x1010/Unit and range from 1.9-9.2x1010/Unit, the mean residual white blood cells was 18.96±16.69x106/Unit and ranged from 0.0-83.6x106/Unit Vs a mean of 13.32±13.12x106 and the rangefrom 0.0-57.6x106/Unit,the contaminated red blood cells had a mean of 1.41±0.78x109/Unit and ranged from 0.0-3.20x109/Unit Vs a mean of 1.33±0.74x109/Unit and range from 0.0-3.04x109/Unit, swirling score had a mean of 2.94±0.24 score and ranged from 2-3 score Vs a mean of 1.92±0.63 score and range from 1-3 sore and the mean pH was 7.94±0.20 and range from 7.4-8.2 Vs a mean of 7.72±0.23 and range from 7.3-8.1 for day one and day five respectively. On day one 38 %,( 19) of the platelet concentrate had a volume of 50-70 ml, only40 %, (20) had a platelet count of >5.5x1010/Unit , 4% (2) of the platelet concentrates did not have detectable red cell contamination,score 3 swirling was observed in 94 % , (47) of units and only 6% , (3) revealed score 2 swirling. No unit had score 1 swirling and the pH was above 6.2 in all units. On day five only 30%, (15) of the concentrates had a platelet count of ≥ 5.5x1010/Unit,16%, (8) of units had score 3, and thepH was maintained above 6.2 in all units. The study revealed that only less than half of the platelet concentrates units fulfilling minimum quality requirement specifications for platelet counts while all units had pH well above quality requirement specifications. Also there was significant decrease in the quality parameters at day five than day one (P value <0.05).This indicated that further standardization on the methods of platelet concentrate collections, preparation and storage is required.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectParameters of Plateletsen_US
dc.subjectPlatelets Concentrateden_US
dc.titleAssessment of Quality Parameters of Platelets Concentrated Prepared at ElmekNimer University Hospital Blood Bank-ShendiCityen_US
dc.title.alternativeتقويم عوامل الجودة للصفائح الدموية المركزة المحضرة في بنك الدم لمستشفى المك نمر الجامعي-مدينة شنديen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Laboratory Science

Files in This Item:
File Description SizeFormat 
Assessment of Quality Parameters....pdfTitle259.85 kBAdobe PDFView/Open
Introduction and literature review.pdfResearch774.38 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.