Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11957
Full metadata record
DC FieldValueLanguage
dc.contributor.authorIBRAHIM, MOHAMED EL-WIDAA
dc.contributor.authorSupervisor - IKHLAS ABD AL-AZIZ HASAN
dc.date.accessioned2015-11-22T07:26:37Z
dc.date.available2015-11-22T07:26:37Z
dc.date.issued2015-03-26
dc.identifier.citationIBRAHIM,MOHAMED EL-WIDAA.Optimization of Radiation/MOHAMED EL-WIDAA IBRAHIM;IKHLAS ABD AL-AZIZ HASAN.-khartoum:Sudan University of Science and Technology, College of Medical Radiologic Science ,2015.-76p. : ill . :28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11957
dc.descriptionThesisen_US
dc.description.abstractThis study was conducted to evaluate the effective dose in adults during the examination of the brain computed tomography. The motivations for this study that frequency of the brain CT test is high and the radiation field of brain CT contain sensitive organ like eyes. By mathematical equation after it has been collecting the factors that affect the amount of radiation from producer ray tube in addition to the two factors CT radiation dose index (CTDI) and the dose length product (DLP) .the cancer risk was calculated by special program by used the factor dose length product. This study was done in three different centers on three different devices in the generations to collect 60 samples from (1-7-2014) to (10/03/2015) The study found that the effective dose in the first center (A1) may be worth (3.29 ± 0.55 ) This value is higher than the agreed value of the world while in second center (B2) has reached the value (0.545 ± 0.21) and this was set up by Ali that they value are also acceptable in third center (C3) amounted to value (2.0123 ± 0.24) which is also acceptable.en_US
dc.description.sponsorshipSudan University of Sciences and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectRadiation Dose for Brainen_US
dc.subjectComputerized Tomographyen_US
dc.titleOptimization of Radiation Dose for Brain Computerized Tomographyen_US
dc.title.alternative‫امثلة الجرعة االشعاعية لفحص الدماغ باالشعة المقطعية‬en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Optimization of Radiation ...pdfresearch1.63 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.