Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11800
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMustafa, HaramMohammed Alfateh Mohammed
dc.contributor.authorSupervisor - Abuagla Babiker Mohammed Babiker
dc.date.accessioned2015-11-09T11:09:11Z
dc.date.available2015-11-09T11:09:11Z
dc.date.issued2015-08-10
dc.identifier.citationMustafa,HaramMohammed Alfateh Mohammed.Design of Heart Sound Biometric Access Control System / HaramMohammed Alfateh MohammedMustafa;Abuagla Babiker Mohammed Babiker.-Khartoum: Sudan University of Science and Technology, College of Engineering, 2015 .-134p. :ill. ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11800
dc.descriptionThesisen_US
dc.description.abstractThis project reviews the extent to using of heart sound as biometric system used to identify the person and verify him. Features that have been chosen for this purpose are energy of heart sound signal and power spectrum.The heart sounds were collected from the internet. A matrix laboratory (MATLAB) algorithm was implemented to design a program that used discrete wavelet transform (DWT) for de-noising the signal, continuous wavelet transform (CWT) and Mel Frequency Cepstrum Coefficients (MFCC) for feature extraction and then a databases were build holding sounds features. Finally, Euclidean distance was used for classification sounds and display result depending on mode of operation (identification or verification mode). The program code was implemented in Graphical User Interface (GUI) to easy use of application. Then RS232 was interfaced between it and simulation circuit that consist of ATMEGA 16 (microcontroller), which simulate program via Bascom-AVR as programming language then Proteus was used to verify the code, it was displayed the name of person if the application in identification mode or allowed to access if in verification mode. The application which was programmed and simulated gave a 22.35% error in identification mode when used energy signature and gave a 15.29% error in identification mode when used power spectrum signature.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMechatronic Engineeringen_US
dc.subjectControl Systemen_US
dc.subjectHeart Sounden_US
dc.subjectSound Biometricen_US
dc.titleDesign of Heart Sound Biometric Access Control Systemen_US
dc.title.alternativeتصميم نظام تحكم للولوج بإستخدام صوت القلب كبصمة حيويةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Design of Heart ...pdfResearch3.62 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.