Please use this identifier to cite or link to this item:
https://repository.sustech.edu/handle/123456789/11768
Title: | Assessment of Sensitivity and Specifity Immunochromatograophy Test And ELISA for detecting Human Immunodeficiency Virus Antibodies among Screening patients in Khartoum state |
Other Titles: | تقدير حساسية وخصوصية الاختبار بواسطة تقنية الكروماتوغرافي الممنع مقارنة بالاليزا لوجود الاجسام المضاده لفيروس نقص المناعه المكتسب(الايدز) لدي الفاحصين المتطوعين بولاية الخرطوم |
Authors: | Eisa, Sayed Mutasim Abd Alwahab Ahmed Supervisor,- Yousif Fadlalah Hamed Elnil |
Keywords: | Immunochromatograophy Test Immunodeficiency Virus |
Issue Date: | 1-Jun-2015 |
Publisher: | Sudan University of Science & Technology |
Citation: | Eisa,Sayed Mutasim Abd Alwahab Ahmed.Assessment of Sensitivity and Specifity Immunochromatograophy Test And ELISA for detecting Human Immunodeficiency Virus Antibodies among Screening patients in Khartoum state/Sayed Mutasim Abd Alwahab Ahmed Eisa;Yousif Fadlalah Hamed Elnil.-Khartoum:Sudan University of Science & Technology,Medical Laboratory Science,2015.-88p.:ill.;28cm.-M.Sc. |
Abstract: | Human Immunodeficiency Virus ( HIV) is global and serious problem , with increase in mortality and morbidity worldwide. This was prospective , descriptive and cross sectional study aimed to assess the level of HIV Ab using the ICT and ELISA for detecting Ab and Ag (p24) .It was conducted among Screening patient in Khartoum state (National Public Health Laboratory) from 1 April to 30 June (2015) on a total of eighty nine (n=89)to compare the sensitivity and specificity of immunochromatographic test and ELISA in detecting HIV Ab .All subject examined in this study from both sex male and females . 14 (15.7 %) of screening patients were positive for HIV Ab by ICT, Where it decrease to 13(14.6%) by ELISA procedure run on the same serum sample .there was one false negative result when tested by ICT . total of previous blood transfusion .only 7 % who had positive for HIV Ab when tested by ELISA . The highest prevalence was on the age group (21- 40) years and low rate ( 61 – 80). The result obtained show that the ICT technique has 100% ,98.6 % respectively sensitivity and specificity for detection of HIV Ab .While ELISA revealed 100% for both sensitivity and specificity .Results showed that the ICT used in this study for HIV Ab was less specific compare to ELISA . Among married screening patients 55/89 (61.8 %) higher than single 34/89(38.2%) positive cases were 7/55(7.9%) among married and 6/34( 6.7%) among single .were examined by ELISA . In those who has previous surgical operation and multi transfusion only 7 % who had positive for HIV when tested by ELISA . |
Description: | Thesis |
URI: | http://repository.sustech.edu/handle/123456789/11768 |
Appears in Collections: | Masters Dissertations : Medical Laboratory Science |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Assessment of Sensitivity.......pdf | Research | 18.56 MB | Adobe PDF | View/Open |
SCAN0000.PDF | Scan | 2.82 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.