Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11648
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBabiker, Babiker
dc.contributor.authorSupervisor - Yousif Mohamed Yousif Abdalla
dc.date.accessioned2015-10-11T08:55:10Z
dc.date.available2015-10-11T08:55:10Z
dc.date.issued2015-07-31
dc.identifier.citationBabiker ,Babiker .Assessment of Radiation Doses of Pediatric Chest X-Ray :Ibrahim Mohammed Osman Babiker /Yousif Mohamed Yousif Abdallah.-khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science2015.-44p. : ill . ;28cm .-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11648
dc.description.abstractThis study deals with evaluation of pediatric patient dose received by patients undergoing radiological examinations. Radiation doses to patients from chest X-rays radiography. Which is the most common pediatric X-rays examinations were studied in two hospitals Khartoum hospital (KH), and Omdurman hospital (OH), in Khartoum state, Sudan. The ESD values was measured, analyzed and compared to those reported by the European guidelines on quality criteria for diagnostic radiographic images EUR 16260EN. Entrance surface dose (ESD) was determined from exposure settings using DosCal software. Totally, 50 patients were included in this study. Mean ESDs obtained from for pediatric chest radiography in (KH) hospital recorded in this work was 0.0542 mGy, and .0487 mGy for (OH) hospital. The mean ESDs per chest radiographic image ranged between 0.054 and 0.031 mGy in (KH) and (OH) respectively per exposure, which is slightly lower than the corresponding values reported in the DRLs reported in European guidelines on quality criteria for diagnostic radiographic images EUR 16260EN. Patient’s doses were high in departments using single-phase generators compared to those using constant potential. The results presented in this work will serve as a baseline data needed for deriving reference doses for pediatrics X-rays examinations in Sudan. The mean organ equivalent dose assessed from ESDs measured values for (KH) and (OH) using CHILDOSE (NRPB-SR279) to lung, breast, thyroid, liver, kidney , bladder, stomach and testis were 0.022, 0.038, 0.026, 0.014, 0.001, 0.006, 0.00131 and 0.00002 mSv for (KH) , 0.0121, 0.0224, 0.0149, 0.008, 0.001, 0,0035, 0,006 and 0.00007 mSv for (OH) respectively. The overall effective doses obtained from this study were 0.0092 and 0.0053 mSv for (KH) and (OH) respectively.
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectCollege of Radiologyen_US
dc.subjectMedical Diagnosticen_US
dc.subjectAssessment of Radiationen_US
dc.subjectDoses of Pediatric Chest X-Rayen_US
dc.titleAssessment of Radiation Doses of Pediatric Chest X-Rayen_US
dc.title.alternativeتقويم الجرعة الإشعاعية للأطفال في تصوير الأشعة السينية للصدرen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Research last.pdfResearch 561.27 kBAdobe PDFView/Open
List of Tables last.pdfTables6 kBAdobe PDFView/Open
Abstract English .pdfAbstract203.87 kBAdobe PDFView/Open
First page.pdfف137.32 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.