Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11419
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHamad, Hesa Abdalla Agaban-
dc.contributor.authorSupervisor,- Hussein Ahmed Hassan-
dc.date.accessioned2015-08-05T10:05:54Z-
dc.date.available2015-08-05T10:05:54Z-
dc.date.issued2014-12-01-
dc.identifier.citationHamad,Hesa Abdalla Agaban.Study Of Image Quality In Digital Radiography\Hesa Abdalla Agaban Hamad ; Hussein Ahmed Hassan .- Khartoum : Sudan University of Science and Technology , college of Medical Laboratory Science , 2014 .- 69p. : ill. ; 28cm.-M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11419-
dc.descriptionThesisen_US
dc.description.abstractThe objective of the research was to study the image quality in digital radiography in Modern Medical Center. the data were collected the from radiography department in Modern Medical Center for 40 patient (males and femals) in adult with average age (15-45 ) ,20 patients under went to chest x ray image PA ,10 chest performed by digital radiography (DR) and other 10 chest performed by computed radiography (CR). 20 patients Lumbar spine, 10 spinal cord performed by digital radiography and other 10 performed by computed radiography, this images evaluated by this score (excellent=4 ,very good=3,good=2,acceptable=1) in all each factor images by ten senior graduated students in sudan university and toke the average of images . The percentage of contrast in chest images in DR is 93% and in CR is 91%, the percentage of resolution in chest images in DR is 93.4% and in CR is 90.3%, the percentage of artifact in chest images in DR is 96% and in CR is 93% and the percentage of noise in chest images in DR is 97% and in CR is 94.5% ,the percentage of contrast lumbar spine images in DR is 91.3% and in CR is 87.4%, the percentage of resolution lamer spine images in DR is 93.1% and in CR is 87.7%, the percentage of artifact lumbar spine images in DR is 76.2% and in CR is 72.3% and the percentage of noise lumbar spine images in DR is 97% and in CR is 83.8%. This means the all percentages of images parameters in DR is better than in CR.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectImageen_US
dc.subjectDigital Radiographyen_US
dc.titleStudy Of Image Quality In Digital Radiographyen_US
dc.title.alternative‫دراسة لجودة الصورة في التصوير اﻻشعاعي الرقمي‬en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Laboratory Science

Files in This Item:
File Description SizeFormat 
Study Of Image ....pdfTitle95.99 kBAdobe PDFView/Open
Abstract.pdfabstract524.72 kBAdobe PDFView/Open
Resarch.pdfResearch1.46 MBAdobe PDFView/Open