Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/11216
Full metadata record
DC FieldValueLanguage
dc.contributor.authorElteep, Motwakil Elsiddig
dc.contributor.authorSupervisor,- Yousif Mohamed Yousif Abdallah
dc.date.accessioned2015-06-30T07:56:36Z
dc.date.available2015-06-30T07:56:36Z
dc.date.issued2015-02-01
dc.identifier.citationElteep, Motwakil Elsiddig. Measurement of the Esophageal Motion in External Beam Irradiation/ Motwakil Elsiddig Elteep; Yousif Mohamed Yousif Abdallah.- khartoum: Sudan University of Science and Technology, College of Medical Radiologic Science, 2015.- 36p. : ill. ; 28cm.- M. Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/11216
dc.descriptionThesisen_US
dc.description.abstractThis study aimed to measure the shift of esophagus motion in external beam irradiation which lead to increase accuracy of determination of both PTV and ITV resulting in increase and enhancing therapeutic ratio and minimizing toxicity of both neighboring structure and rest volume of esophagus . This study was collected when treated patient is simulated using CT simulator of esophagus and chest organ treatment of cancer where the respiratory gated, three dimensional CT imaging of the full expiratory motion and minimum and maximum displacement was measured based in CT data. The data analyzed with Mat lab program under windows with t-test to assess the Motion of Esophagus in Radiation Therapy, The final result show that there was a difference in average between the oesophagus position regarding to (X-reading) of the inspiration phase which is equal to 10.16 + 3.31 and 10.6 +3.02. This difference was not significant at p= .05 using t-test with t= -9.74 and p=0.001. As well as here is a difference in average between the oesophagus position regarding to (Y-reading) of the inspiration phase which is equal to 8.6 + 2.02 and 12.7 +1.12. This difference was significant using t-test with t= .162 and p=0.87en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectRadiologic Scienceen_US
dc.subjectBeam Irradiationen_US
dc.subjectMeasurement of the Esophagealen_US
dc.subjectالحركة في الخارجية شعاعen_US
dc.titleMeasurement of the Esophageal Motion in External Beam Irradiationen_US
dc.title.alternative‫قياس حركة المرئ في التشعيع بالحزمة من‬ الخارجen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Measurement of the ... .pdftitle 76.11 kBAdobe PDFView/Open
Abstract.pdfAbstract.122.13 kBAdobe PDFView/Open
Research.pdfResearch.325.69 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.