Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/10996
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAwad, Tarig Tilal Ahmed-
dc.date.accessioned2015-06-09T10:09:53Z-
dc.date.available2015-06-09T10:09:53Z-
dc.date.issued2015-01-01-
dc.identifier.citationAwad , Tarig Tilal Ahmed . Assessment of Spatial Resolution Of planner digital X-Ray Machine By Using Modulation (Transfer Function(MTF \ Tarig Tilal Ahmed Awad ; Mohammed Elfadil Mohamed Gar-elnabi .- Khartoum: Sudan University for Science and Technology, College of Medical Radiologic Science,45p. : ill. 28 cm.-Ms.c.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/10996-
dc.descriptionThesisen_US
dc.description.abstractMedical imaging of human body requires some form of energy, the energy used to produce the image must be capable of penetrating tissues then a multi step process by which information concerning patient anatomy and physiology was gathered and displayed with the modern technology. Radiographic images are useful for very wide range of medical indications. The image quality that is obtained from medical imaging device involve compromise better X-Ray image can be made when the radiation dose to the patient is optimum. Spatial resolution is usefulness in determining the accurate diagnosis, modulation transfer function MTF give the most complete characterization of the spatial resolution of the imaging device. This study was conduct in Antalia Medical Center, Khartoum, Sudan and the measurement was performed using X-check FLU phantom. The results of this study showed that the best resolution scored at higher energy 90 and 85 kv, where 100% resolution was scored for bar phantom with a frequency of 0.5 cycle/mm, 94% for 0.56 cycle/mm, 80.1% for 0.63cycle/mm and 75% for 0.71 cycle/mm all at 90 kv. The results showed that as the thickness of the bar decreases (it is frequency increases) the resolution deteriorateen_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectAshah digital-raysen_US
dc.subjecta function mutationen_US
dc.subjectimage clarityen_US
dc.subjectdegree of image clarityen_US
dc.titleAssessment of Spatial Resolution Of planner digital X-Ray Machine By Using Modulation (Transfer Function(MTFen_US
dc.title.alternative‫تقويم درجة وضوح الصورة لجهاز العشعة السينيه‬ ‫الرقمية باستخدام دالة التحور‬en_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Spatial ....pdfTitle29.27 kBAdobe PDFView/Open
Abstract.pdfAbstract70.67 kBAdobe PDFView/Open
Research.pdfResearch1.02 MBAdobe PDFView/Open