Evaluation of conventional X-ray unit in medical imaging department

Show simple item record

dc.contributor.author Elhassan, Marwa Abd Alla Mohammed
dc.contributor.author Supervisor ,- Alnazier Osman Moh
dc.date.accessioned 2014-05-08T11:19:34Z
dc.date.available 2014-05-08T11:19:34Z
dc.date.issued 2012-10-01
dc.identifier.citation Elhassan,Marwa Abd Alla Mohammed .Evaluation of conventional X-ray unit in medical imaging department/Marwa Abd Alla Mohammed Elhassan;Alnazier Osman Moh. Hamza.-Khartoum:Sudan University of Science and Technology,College of Engineering,2012.-61p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/4866
dc.description Thesis en_US
dc.description.abstract Conventional radiography or X-ray is part of diagnostic imaging tool for detection and diagnosis of diseases. Since the X-ray was discovered in 1895 to 2010 more than 5 billion medical imaging studies were published worldwide. However, there are certain harmful biological effects were recorded; for that the concept of quality control and radiation protection was developed to minimize these effects. But now in most of developing countries there is lack of awareness and interest of radiation protection and quality control in radiology department even sometimes there is no QC tools, which can lead to improper dose, risk to the machine, error in reading and image quality. The present study had been carried out to evaluate the radiation protection and quality control measures in 15 radiology department in Khartoum state. Data had been collected divided in to two main parts, first part radiation protection tests, which include visual inspection test, room dimension, and scattered radiation. Secondly quality control tests which include output accuracy, linearity, reproducibility, collimator, filtration, beam alignment. The data were processed, analyzed and compared with standard tolerance of radiation protection and quality control test to determine whether these units comply with standards or not, and suggest any modification should be necessary to correct the observed defects. The result of this study showed that, the average of acceptable percentage in all the units was 70% and 74% in radiation protection test and quality control test respectively. This percentage generally acceptable for all units. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Biomedical Engineering en_US
dc.subject Conventional X-ray en_US
dc.subject Medical Imaging en_US
dc.subject Radiography en_US
dc.subject Diagnostic Imaging Tool en_US
dc.title Evaluation of conventional X-ray unit in medical imaging department en_US
dc.title.alternative ‫تقويم أداء أجهزة الاشعة السينية بأقسام التصوير الطبي‬ en_US
dc.type Thesis en_US