SUST Repository

Comparison of Plasma Sodium and Potassium Results Obtained by the Flame photometer and Ion Selective Electrode Techniques

Show simple item record

dc.contributor.author Aboshouk, Nayla Ahmed Mohamed
dc.contributor.author Supervisor,- Abdelhafiz Hassan Khattab
dc.date.accessioned 2014-01-30T06:54:44Z
dc.date.available 2014-01-30T06:54:44Z
dc.date.issued 2009-03-01
dc.identifier.citation Aboshouk,Nayla Ahmed Mohamed.Comparison of Plasma Sodium and Potassium Results Obtained by the Flame photometer and Ion Selective Electrode Techniques/Nayla Ahmed Mohamed Aboshouk;Abdelhafiz Hassan Khattab.-Khartoum:Sudan University of Science and Technology,college of Medical Laboratory Science,2009.-48p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/3299
dc.description Thesis en_US
dc.description.abstract This study was carried to compare results of plasma sodium and potassium that, measured by flame photometer and ion selective electrode (ISE). The analysis was done in International Private Hospital (diagnostic center) and Ombdda Teaching Hospital. Fifty specimens were included in the study, 20 specimens with normal sodium and potassium, 15 specimens with low sodium and 15 specimens with high potassium levels. The specimens (plasma) were measured by both techniques (flame photometer and ISE) and the results presented in tables and figures. Statistical analysis of the result (independent t-test) showed there was a significant difference obtained by the two instruments, which was due to variation in plasma water, interference from other ions, residual liquid junction and binding of ion to protein or other legend when using ISE. Fluctuation in light source may be the cause in the variation of results when using flame photometer. The results show that ISE is better than flame photometer in determination of plasma sodium and potassium. Further studies must be done for accuracy and precision for any new methods. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Plasma Sodium en_US
dc.subject Plasma Potassium en_US
dc.subject Flame photometer-Plasma en_US
dc.subject Ion Selective Electrode-Plasma en_US
dc.title Comparison of Plasma Sodium and Potassium Results Obtained by the Flame photometer and Ion Selective Electrode Techniques en_US
dc.title.alternative ‫مقارنة نتائج الصوديوم والبوتاسيوم فى البلازما‬ ‫المتحصل عليها بتقنية جهاز الطيف اللهبى وجهاز‬ القطب الايونى الانتقائى الكهربائى‬ en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account