SUST Repository

Effect of delayed separation plasma glucose levels when using different anticoagulants

Show simple item record

dc.contributor.author Medani, Muntasir Abbas Makki
dc.contributor.author Supervisor,- Tawfig Khogali Wahbi
dc.date.accessioned 2013-11-21T07:55:32Z
dc.date.available 2013-11-21T07:55:32Z
dc.date.issued 2010-01-01
dc.identifier.citation Medani,Muntasir Abbas Makki.Effect of delayed separation plasma glucose levels when using different anticoagulants/Muntasir Abbas Makki Medani;Tawfig Khogali Wahbi.-Khartoum:Sudan University of Science and Technology,college of Medical Laboratory Science,2010.-33p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2422
dc.description Thesis en_US
dc.description.abstract This study was conducted during the period January 2010 to June 2010, in Khartoum teaching hospital, Khartoum state on 50 healthy and diabetic patient ( 20-71 years). They were divided into tow groups. The first group included 25 apparently healthy individuals with normal blood Glucose level as a control groups. Blood glucose level was measured collected in fluoride oxalate container and lithium heparin container. The second group includes 25 diabetic patients age range 20-71 years. Blood glucose level was measured also collected in fluoride oxalate containers and lithium heparin containers. This study it was found that there is significant decrease in concentration of blood glucose when measure immediately and after 6 hours when collected in lithium heparin container (p<0.05) in the diabetic patient .Also in the normal group there was a significant decrease in concentration of blood glucose when measured immediately and after 6 hours in lithium heparin container (p<0.05). Blood glucose concentration has no significant decrease when measured immediately and after 6 hours in fluoride oxalate container(p>0.05) in diabetic patients .Also in normal group there was no significant decrease in blood concentration when measured immediately and after 6 hours in fluoride oxalate container (p>0.5). en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Plasma Glucose en_US
dc.title Effect of delayed separation plasma glucose levels when using different anticoagulants en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account