SUST Repository

Measurement of Some Hematological Parameters of Umbilical Cord Blood of Newborns in Khartoum Teaching Hospital

Show simple item record

dc.contributor.author Ali, Gada Elamin Mohammed
dc.contributor.author Supervisor,- Babiker Ahmed Mohamed Ahmed
dc.date.accessioned 2013-11-10T10:18:14Z
dc.date.available 2013-11-10T10:18:14Z
dc.date.issued 2011-01-01
dc.identifier.citation Ali,Gada Elamin Mohammed.Measurement of Some Hematological Parameters of Umbilical Cord Blood of Newborns in Khartoum Teaching Hospital/Gada Elamin Mohammed Ali;Babiker Ahmed Mohamed Ahmed.-Khartoum:Sudan University of Science and Technology,college of Medical Laboratory Science,2011.-60p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2146
dc.description Thesis en_US
dc.description.abstract This cross-sectional descriptive and analytical study which is carried out in Khartoum Teaching Hospital to identify the values of some hematological parameters of cord blood. Hundred cord blood samples were collected in Khartoum Teaching Hospital by experienced mid wives. Cord blood samples were collected at the time of the delivery (normal vaginal deliveries), three millimeter of blood was drained into the sterile container containing K2EDTA.sex and health conditions of the infant and mother were written in questionnaire. The study revealed that mean + SD value of Hemoglobin concentration was 14.5+ 1.7mg/dl, hematocrit was 44.5+ 5.6%, MCV was 103 +7.6fl , MCH 33.5 +2.8pg , MCH C 32.3+1.4% respectively. The study revealed that the mean values for red cell count was (4.3 + 0.7) ×1012/l, cord blood nucleated red blood cells (nRBCs) count (0.5+1.1)/100WBC. Total leukocyte count with mean of (11.8+ 4.8) ×109/l, the white blood cell differential count revealed that mean + SD of neutrophil was 43.9+11.2% and lymphocytes was 51.1+10.8% respectively. The mean values of platelet count in study group was (230+62.7)× 109/l, reticulocyte count in this study showed that mean reticulocyte count 3.7+1.2. However no significant difference was found between gender of Neonate and the mean values of some hematological parameters of cord blood. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Newborns-Blood-Measurements en_US
dc.title Measurement of Some Hematological Parameters of Umbilical Cord Blood of Newborns in Khartoum Teaching Hospital en_US
dc.title.alternative قياس بعض معايير دم الحبل السري في الاطفال حديثي الولادة في مستشفي الخرطوم التعليمي
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account