SUST Repository

Comparison between Plasma Glucose Concentration in Fluoride Oxalate and Ethylene Di-amine Tetra Acetate (EDTA) Anticoagulants

Show simple item record

dc.contributor.author AL-Safi, Safaa Ayoub Boshara
dc.contributor.author Salih, Leina Mohammed Ali Mohammed
dc.contributor.author Supervisor,- Khalida Mirghani Hamza
dc.date.accessioned 2014-12-25T10:17:35Z
dc.date.available 2014-12-25T10:17:35Z
dc.date.issued 2014-01-01
dc.identifier.citation AL-Safi , Safaa Ayoub Boshara . Comparison between Plasma Glucose Concentration in Fluoride Oxalate and Ethylene Di-amine Tetra Acetate (EDTA) Anticoagulants / Safaa Ayoub Boshara AL-Safi , Leina Mohammed Ali Mohammed Salih ; Khalida Mirghani Hamza .- Khartoum : Sudan University of Science and Technology , Medical Laboratory .- 71p . : ill;28cm.- Bachelor's Search. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/9254
dc.description Thesis en_US
dc.description.abstract This study was carried out in Al-Madeina Al-Monwara clinic in AL-jreaf Shrege during period 2013-2014, to measure glucose concentration using Fluoride Oxalate anticoagulant compared to EDTA anticoagulant during different periods of time (immediately after collection (0), after 2 hours and after 4 hours); to determine the effect of time in glucose concentration in each anticoagulant. Fifty (50) subjects with different age groups were informed about the study and agreed for the participation. Five ml of venous blood sample was collected in both anticoagulants 2.5 ml for each sample. Plasma sample was separated using centrifuge, the concentration of glucose was determined during different periods using Digital Colorimeter. The results obtained and analyzed using software program (SPSS) to give means reduction ± SD of concentrations in both anticoagulants. The results showed that the differences between glucose concentrations in Fluoride Oxalate anticoagulant compared to EDTA anticoagulant is insignificant, while the difference between glucose concentrations during different periods of time in each anticoagulant is significantly different. An mean variation of glucose concentrations between (0- 2) hours is 11.7 mg/dl and 14.2 mg/dl in Fluoride Oxalate and EDTA anticoagulants respectively, between (2-4) hour is 13.8 mg/dl and 13.7 mg/dl respectively, and between (0-4) hours is 25.6 mg/dl and 27.8 mg/dl respectively. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Laboratory en_US
dc.subject Clinical Chemistry en_US
dc.subject Plasma Glucose Concentration en_US
dc.subject Fluoride Oxalate en_US
dc.subject Anticoagulants en_US
dc.subject Ethylene Di-amine Tetra Acetate (EDTA) en_US
dc.title Comparison between Plasma Glucose Concentration in Fluoride Oxalate and Ethylene Di-amine Tetra Acetate (EDTA) Anticoagulants en_US
dc.title.alternative مقارنة بين تركيز جلكوز البلازما في مائع التجلط أوكسلات الفلورايد en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account