SUST Repository

Determination of plasma sodium and potassium levels using flame photometry and ion selective electrode

Show simple item record

dc.contributor.author AbdAlsalam, Hana Hussain
dc.contributor.author Lazim, Roqia Ali Adam
dc.contributor.author Supervisor,- Khaldah Mirghani Hamza
dc.date.accessioned 2014-12-25T10:09:53Z
dc.date.available 2014-12-25T10:09:53Z
dc.date.issued 2014-06-01
dc.identifier.citation AbdAlsalam , Hana Hussain . Determination of plasma sodium and potassium levels using flame photometry and ion selective electrode \ Hana HussainAbdAlsalam , Roqia Ali Adam Lazim ; Khaldah Mirghani Hamza .- Khartoum : Sudan University Of Science And Technology , Medical Laboratory Science , 2014 .- 50 p . : ill ; 28 cm .- Bachelors ' Search . en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/9252
dc.description Thesis en_US
dc.description.abstract The study aimed to measure plasma sodium and potassium concentrations using flame photometry and ion selective electrode methods. Fifty (50) apparently healthy students in Sudan University of different age were selected to assess the comparison between sodium and potassium plasma concentration measuring by flame photometer )JENWEY models PFP7 and PFP7/C) and ion selective electrode (EASYLITE), all samples were selected from Sudan University of Science and Technology after agreement of eachindividual at February 2014, three ml from each individuals was taken in a heparin container. The results showed that significantly difference in sodium plasma concentration average mean (134.9±8.90)mmol/L and (138.4±2.03) mmol/L measured by flame photometer and ion selective electrode respectively (p. value 0.008), no significant difference in concentration of potassium when measured by two methods (p. value 0.17). The results showed insignificant weak positivecorrelation between flame photometer and ion selective electrode in plasma sodium concentration (p. value .907) (r value .017), but significant weak positive correlation between both methods was observed in plasma potassium concentration (p. value .142) (r value .211). en_US
dc.description.sponsorship Sudan University Of Science And Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University Of Science And Technology en_US
dc.subject Medical Laboratory Science en_US
dc.subject Microbiology en_US
dc.subject plasma en_US
dc.subject selective electrode en_US
dc.title Determination of plasma sodium and potassium levels using flame photometry and ion selective electrode en_US
dc.title.alternative تحديد مستويات الصوديوم والبوتاسيوم في البلازما باستخدام الفليم فوتوميتري و الايون سيليكتف اليكترود en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account