SUST Repository

Application and quality control of Infra red radiation in physiotherapy in Alssafa Physiotherapy Hospital in Sudan

Show simple item record

dc.contributor.author Ibrahim, Hassan Mohammed
dc.contributor.author Supervisor-Osman Mustafa Muқhtar
dc.date.accessioned 2014-11-19T07:30:11Z
dc.date.available 2014-11-19T07:30:11Z
dc.date.issued 2006-08-01
dc.identifier.citation Ibrahim,Hassan Mohammed.Application and quality control of Infra red radiation in physiotherapy in Alssafa Physiotherapy Hospital in SudanHassan Mohammed Ibrahim;Osman Mustafa Muқhtar . -Khartoum : Sudan University of Science And Technology, College of Medical Radiology , 2006.-50 p:Ill:28 cm.- M.S.c en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/8112
dc.description Thesis en_US
dc.description.abstract The use of infrared radiation in physiotherapy plays a very important role to relieve pain by increasing blood flow through tissues and remove waste products from the targeted area, if it is used in scientific manner for example the time of duration for exposure as it recommended is 15 to 20 minutes and reach’s 30 minutes in some chronic cases. Also the distance between the source and the skin surface is in the range of 60cms to 90cms٫ for chronic and acute conditions respectively. On the other hand the lamp used to produce infrared radiation must be prepared in a certain specifications e.g. it is power density and it is efficiency must be known . By using digital thermometer to measure the temperature and using a measuring tape to measure the distance between the source and the skin surface so as to confirm the variation in the factors mentioned above. The researcher assumes that the source emission is 250 watt as it written on the lamp for chronic cases٫ the standard distance is 60 cm and for acute cases is 90 cm while the standard time for both is 20 minutes. The real doses given are different from session to session. Some of them are under dosed and others over dosed. The researcher worked out the optimum doses at specified times and distances above and tabulated his findings. He recommended standard values to proper treatment of acute and chronic en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Sudan en_US
dc.subject quality control en_US
dc.subject physiotherapy en_US
dc.subject Infra-red radiation en_US
dc.title Application and quality control of Infra red radiation in physiotherapy in Alssafa Physiotherapy Hospital in Sudan en_US
dc.type Thesis en_US