SIMULATION OF STANDARD TELECONTROL PROTOCAL IEC 6087O-5-101

Show simple item record

dc.contributor.author ELMANSOUR, TARIG MOHAMED
dc.contributor.author Supervisor - ABDEL RASOUL JABAR ALZUBAIDI
dc.date.accessioned 2014-11-17T08:44:47Z
dc.date.available 2014-11-17T08:44:47Z
dc.date.issued 2006-11-01
dc.identifier.citation ELMANSOUR,TARIG MOHAMED .SIMULATION OF STANDARD TELECONTROL PROTOCAL IEC 6087O-5-101/TARIG MOHAMED ELMANSOUR;ABDEL RASOUL JABAR ALZUBAIDI.-Khartoum:Sudan University of Science & Technology,College of Engineering,2006.-58P. : ill. ; 28Cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/8058
dc.description Thesis en_US
dc.description.abstract The use of the telecontrol protocols helps developing of control systems. Technical and commercial competitions produce several protocols with different functions and specifications. This leads International Electrotechnical Commission to create standard protocol for telecontrol systems. As a result of the development of communication systems, the International Electrotechnical Commission produced a series of telecontrol protocols IEC60870-5 that contains several protocols for different purposes. The IEC60870-5-101 is used to link two stations, primary and secondary stations, while the IEC60870-5-103 is used specially to transfer signals and data of protection equipments. The IEC60870-5-104 is used in telecontrol networks and can be easily connected to computer networks. For this simulation, the IEC60870-5-101 was selected for its importance due to its widely spreading use among the telecontrol systems, and it is also considered as a base structure for modern telecontrol systems such as IEC60870-5-104. The simulation was made by the Delphi programming language to link the primary and secondary stations using IEC60870-5-101 protocol. Measured values with floating point numbers have been transferred from a secondary station to a primary station. All the simulation levels for construction and extraction of telecontrol messages were implemented successfully. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Electronic Engineering en_US
dc.subject Electronic Control en_US
dc.subject Microprocessors en_US
dc.subject TELECONTROL PROTOCAL en_US
dc.subject TELECONTROL PROTOCAL en_US
dc.subject IEC60870-5-101 en_US
dc.title SIMULATION OF STANDARD TELECONTROL PROTOCAL IEC 6087O-5-101 en_US
dc.type Thesis en_US