SUST Repository

A COMPARATIVE STUDY OF IEC101, DNP3 and MODBUS SCADA PROTOCOLS

Show simple item record

dc.contributor.author Ismail, Abdalla Hussein
dc.contributor.author Supervisor - Tarig Khalifa Gafar
dc.date.accessioned 2014-08-23T06:48:15Z
dc.date.available 2014-08-23T06:48:15Z
dc.date.issued 2009-03-01
dc.identifier.citation Ismail,Abdalla Hussein.A COMPARATIVE STUDY OF IEC101, DNP3 and MODBUS SCADA PROTOCOLS/Abdalla Hussein Ismail;Tarig Khalifa Gafar.-Khartoum :Sudan University Of Science And Technology,College of Engineering,2009.-101P:ill;28Cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/6774
dc.description Thesis en_US
dc.description.abstract In the last few decades, a new market appears as new horizon in the industrial field, “Automation” Understanding this subject is based on the data communication and related subjects, understanding Supervisory Control and Data Acquisition (SCADA) as an automation system need good knowledge of protocols that used for data exchange between different system terminals. Unfortunately SCADA protocols are so complex and need analytical mind to evaluate system performance, system behavior beside error handling .It is also difficult to answer the question of “which SCADA protocol to choose for a specific SCADA system”. In this research an analytical approach was employed to answer the most common questions regarding this subject where two dominant SCADA protocols are analyzed as master-to-substation protocol and one famous remote terminal unit (RTU)-intelligent electronic device (IED) protocol as an example. The researcher found that each protocol has an advantages and weak points for example at the time that DNP3 has more data objects IEC101 has more addressing capability, while DNP3 has more efficient security but the price is using about 11% of the link frame for security, at the same time IEC has less security method for only 0.4% of the total frame length. Information object addressing was also different between DNP3 and IEC101, while IEC101 uses an application level address, DNP3 do not, but this point makes analysis of DNP3 message difficult task, in practice this is a weak point. It was obvious that field bus protocol (MODBUS) requires only little group of data object. en_US
dc.description.sponsorship Sudan University of Science &Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science &Technology en_US
dc.subject IEC101, DNP3 en_US
dc.subject MODBUS SCADA PROTOCOLS en_US
dc.title A COMPARATIVE STUDY OF IEC101, DNP3 and MODBUS SCADA PROTOCOLS en_US
dc.title.alternative دراسة مقارنة عن مراسم التحكم الاشرافى en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record