SUST Repository

Evaluation of Patient Radiation Dose in Multi Slice Computed Tomography Modalities Examinations

Show simple item record

dc.contributor.author Nemer, Abdelfatah Abdallah
dc.contributor.author Supervisor-Abdelmoneim Adam Mohamed Sulieman
dc.date.accessioned 2014-06-18T11:56:17Z
dc.date.available 2014-06-18T11:56:17Z
dc.date.issued 2012-03-01
dc.identifier.citation Nemer,Abdelfatah Abdallah.Evaluation of Patient Radiation Dose in Multi Slice Computed Tomography Modalities Examinations/Abdelfatah AbdallahNemer;Abdelmoneim Adam Mohamed Sulieman.- Khartoum : sudan university of science and technology,Medical Radiologic science,2012.-194p. : ill .;28cm.-M.sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/5810
dc.description Thesis en_US
dc.description.abstract Computed Tomography (CT) scanning has been recognized as a high radiation dose modality, when compared to other diagnostic X-ray techniques, since its launch into clinical practice since its emergence in 1971. The purpose of this study was to evaluate the patient radiation dose in different CT modalities (16 slice (Alfaisal Hospital (A)), 4 slice (Ibn Alhaitham (B) and dual slice (Alnilain (C)). A total of 95 patients were examined in this study. The data was collected from the following examinations: brain, chest, abdomen and pelvis. 29, 21 and 45 patient from hospital A,B and C respectively. The mean patient doses was 570+/-190.7 mGy.cm for hospital A, 497.89 +/-229.9 mGy.cm for hospital B and 142.5+/-45.96 mGy.cm for hospital C. Patients’ demographic data (age, weight, BMI) were comparable. Dual slice scanner delivered the least radiation dose while 4 and 16 slice scanners delivered the highest radiation dose. Radiation dose variation can be attributed to the scan parameters used from site to site and scanner design. Multi-slice scanners allow higher mAs values, longer scan lengths and multi-phase contrast studies, have also the potential of directly increasing patient doses. CT dose optimisation protocol is not implemented in all departments en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Evaluation en_US
dc.subject Radiation en_US
dc.title Evaluation of Patient Radiation Dose in Multi Slice Computed Tomography Modalities Examinations en_US
dc.type Thesis en_US