| dc.contributor.author | Alameen, SuhaibMohamedsalihAhamed | |
| dc.contributor.author | supervisor -Elhussaien Hassan Ahamed | |
| dc.date.accessioned | 2014-04-02T11:53:21Z | |
| dc.date.available | 2014-04-02T11:53:21Z | |
| dc.date.issued | 2013-07-01 | |
| dc.identifier.citation | Alameen,SuhaibMohamedsalihAhamed.Evaluation of Image Quality and Radiation Dose in Computed Radiography/SuhaibMohamedsalihAhamedAlameen;Elhussaien Hassan Ahamed.-Khartoum : sudan university of science and technology,Medical Radiologic Science ,2013.-53p :ill . ; 28cm. .-M.Sc. | en_US |
| dc.identifier.uri | http://repository.sustech.edu/handle/123456789/4208 | |
| dc.description | Thesis | en_US |
| dc.description.abstract | IV Abstract The assessment of image quality and patient dose from computed radiography for common x-ray examinations namely skull Posterior Anterior and Lateral , chest Posterior Anterior , lumber spine Anterior Posterior and Lateral and pelvis Anterior Posterior radiography was perfumed in three private hospitals in capital Khartoum . image quality evaluated by using threshold contrast-detail phantom (TO. 20). Assessment obtained by average scores from four specialist . This study deals with evaluation of patient dose received by patients undergoing radiological examinations , Three large hospitals in Khartoum were selected and 164 patients made up the sample .The entrance surface doses (ESDs) to patient undertakening four common x.ray examination (skull PA& LAT , chest PA , lumber spine AP & LAT, pelvis AP) were estimated using ionization chamber for air kerma measurements . Exposure settings and patients data were recorded . Result concerning the kilovoltage (KVp) and tube current (mAs) and focus to film distance (FFD) settings . and the ESD values were analyzed and compared (by other hospitals) to those recommended by the EU . discrepancies in the patient doses and techniques used for the examinations studied were found among the different hospitals denoting the importance of establishing a national quality assurance programme and examination protocols to ensure patient doses are Kept as Low as possible . All the examinations studied fulfilled the EU recommendations . The result of image quality show small different between three hospitals which indicate the routine quality assurance and quality control play important role in the equipment performance. | en_US |
| dc.description.sponsorship | sudan university of science and technology | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | sudan university of science and technology | en_US |
| dc.subject | Evaluation | en_US |
| dc.subject | Radiography | en_US |
| dc.title | Evaluation of Image Quality and Radiation Dose in Computed Radiography | en_US |
| dc.type | Thesis | en_US |