SUST Repository

Evaluation of the Sensitivity and Specificity of Immunochromatochgraphy Test in Relation to ELISA for the Diagnosis of Human Immunodeficiency Virus Infection in Omdurman Military Hospital

Show simple item record

dc.contributor.author Hassan, Ranya Abd Al Salam Mohamed
dc.contributor.author Supervisor,- Yousif Fadlalla Hamed Elnil
dc.date.accessioned 2014-03-19T06:28:41Z
dc.date.available 2014-03-19T06:28:41Z
dc.date.issued 2013-01-01
dc.identifier.citation Hassan,Ranya Abd Al Salam Mohamed.Evaluation of the Sensitivity and Specificity of Immunochromatochgraphy Test in Relation to ELISA for the Diagnosis of Human Immunodeficiency Virus Infection in Omdurman Military Hospital/Ranya Abd Al Salam Mohamed Hassan;Yousif Fadlalla Hamed Elnil.-Khartoum:Sudan University of Science and Technology,college of Medical Laboratory Science,2013.-68p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/3982
dc.description Thesis en_US
dc.description.abstract This study was carried out in Omdurman Military Hospital in the period from July to October 2013 on a total of hundred patients to compare between the sensitivity and specificity of Immunochromatographic test (ICT) and indirect HIV ELISA using recombinant antigen. Three (3%) patients were positive for HIV antibodies by ICT and the same patients (three (3%) patients) were positive by ELISA. The infection was identified among patients who have previous blood transfusion (4.3%). This revealed no significant effect (p > 0.05). The commonest infected age group was from 30-40 year (2%), and low rate infection was identified among age group from 52-62 year (1%). The positive results for HIV infection was 2% among males and 1% among females. There is no difference between the two tests (in specificity and sensitivity between ICT and ELISA). Therefore, both tests are reliable for screening HIV antibodies in patient. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Human Immunodeficiency-Virus en_US
dc.subject Human Immunodeficiency-Evaluation en_US
dc.title Evaluation of the Sensitivity and Specificity of Immunochromatochgraphy Test in Relation to ELISA for the Diagnosis of Human Immunodeficiency Virus Infection in Omdurman Military Hospital en_US
dc.title.alternative ‫تقويم حساسية وخصوصية الاختبار بواسطة تقنية‬ ‫الكروماتوغرافي الممنع مقارنة بالاليزا في تشخيص فيروس‬ ‫عوز المناعة البشرى في مستشفي السلاح الطبي أم درمان‬ en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account